文献速递妇产影像儿科影像US

胎儿冠-颏长与头臀长比值作为早孕期三倍体产前超声标志物

Fetal Crown-Chin Length to Crown-Rump Length Ratio as a Prenatal Sonographic Marker for Triploidy at First Trimester.
PubMed 文献 · J Ultrasound Med · 2021-05-21

本研究回顾性分析325例正常胎儿与12例三倍体胎儿的早孕期超声图像,建立冠-颏长(CCL)与头臀长(CRL)的正常参考范围及CCL/CRL比值。正常胎儿CCL随孕龄线性增长,CCL/CRL比值随孕龄下降;全部12例三倍体胎儿CCL/CRL比值均高于第95百分位,以第95百分位为cutoff,检出率100%、假阳性率5%、阳性似然比20。结论认为该比值可作为早孕期筛查三倍体的有效超声标志物。

要点

  • 早孕期三倍体胎儿CCL/CRL比值均高于正常范围第95百分位。
  • 正常胎儿CCL/CRL比值随CRL增加而下降,从0.46(CRL 45mm)至0.41(CRL 84mm)。
  • 以第95百分位为cutoff,CCL/CRL比值筛查三倍体检出率100%、假阳性率5%。

核心结论

  • 胎儿CCL/CRL比值可作为早孕期筛查三倍体的有效超声标志物。

研究设计与样本

  • 回顾性研究,纳入325例正常胎儿与12例三倍体胎儿,由两名经验丰富的超声医师离线测量CCL与CRL并取平均值分析。
  • 建立正常CCL参考范围,并分析正常与三倍体胎儿的CCL/CRL比值。

关键影像表现/征象

  • 正常胎儿CCL随孕龄呈线性增长,从CRL 45mm时的20mm增至CRL 84mm时的36mm。
  • 正常胎儿CCL/CRL比值随孕龄下降,从CRL 45mm时的均值0.46降至CRL 84mm时的0.41。
  • 全部12例三倍体胎儿CCL/CRL比值均高于第95百分位。

诊断标准与关键数值

  • 正常CCL线性回归方程:CCL(mm) = 3.65 + 0.38 CRL,R² = 0.821,P = .000。
  • 正常CCL/CRL比值回归方程:CCL/CRL = 0.502 - 0.001 CRL,R² = 0.093,P = .000。
  • 以CCL/CRL比值第95百分位为cutoff筛查三倍体,检出率100%、假阳性率5%、阳性似然比20。

临床应用与阅片要点

  • 早孕期超声测量CRL时可同时测量CCL并计算CCL/CRL比值,辅助筛查三倍体。
  • 需注意CCL/CRL比值随孕龄变化,应按对应CRL的第95百分位判断是否异常。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the ratio of Crown to Chin length (CCL) to Crown-rump length (CRL) between triploid and normal fetuses at first trimester and establish a reference range of fetal CCL/CRL ratio.

METHODS: Three hundred and twenty-five normal and 12 triploid fetuses were reviewed in this study. The image of fetal Crown-rump length (CRL) was acquired retrospectively. CCL and CRL were measured offline by two experienced sonographers, we obtained each averaged value of CCL and CRL as the final data for analysis. A normal range of CCL was established and CCL/CRL ratio was analyzed in normal and triploid fetuses.

RESULTS: In 325 normal fetuses, CCL increased with gestational age following a linear trend from 20 mm at a CRL of 45-36 mm at a CRL of 84 mm (CCL (mm) = 3.65 + 0.38 CRL, R2 = 0.821, P = .000). The CCL/CRL ratio decreased with gestational age from a mean of 0.46 at a CRL of 45 mm to 0.41 at a CRL of 84 mm (PML/CRL = 0.502-0.001 CRL, R2 = 0.093, P = .000). All 12 triploid fetuses had a CCL/CRL ratio above the 95th percentile. When the 95th percentile are used as cutoff values, the detection rate, false-positive rate, and the positive likelihood ratio are 100%, 5%, and 20, respectively.

CONCLUSIONS: The present study demonstrates that fetal CCL/CRL ratio can be used and effective ultrasound marker in screening for triploidy during the first trimester.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Yang X, Li Y, Wu S, et al. Fetal Crown-Chin Length to Crown-Rump Length Ratio as a Prenatal Sonographic Marker for Triploidy at First Trimester. J Ultrasound Med. 2021. PMID: 34018626. doi:10.1002/jum.15749

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。