文献速递泌尿生殖腹部MR

基于图像增强和T1 mapping特征的前列腺癌Gleason评分预测的新放射组学方法

De Novo Radiomics Approach Using Image Augmentation and Features From T1 Mapping to Predict Gleason Scores in Prostate Cancer.
PubMed 文献 · Invest Radiol · 2021-01-01

本研究在85例经组织学证实的前列腺癌患者中,利用双参数MRI(T2WI、DWI)及66例的T1 mapping,提取322个放射组学特征并经图像增强扩增10倍,采用四种机器学习算法区分Gleason评分6、7和≥8。支持向量机分类准确率最高,为0.92(95%CI 0.62-1.00);图像增强使准确率平均提高0.08(SGB)至0.48(SVM);移除T1 mapping特征后随机森林准确率下降0.16、随机梯度提升下降0.25,且泛化误差升高。

要点

  • 支持向量机区分Gleason 6、7和≥8的准确率达0.92(95%CI 0.62-1.00)。
  • 图像增强使准确率平均提高0.08(SGB)至0.48(SVM)。
  • 移除T1 mapping特征后随机森林准确率下降0.16、随机梯度提升下降0.25。

核心结论

  • 在数据有限时,图像增强和定量T1 mapping特征可能有助于提高双参数MRI放射组学区分不同Gleason分组的准确率并降低泛化误差。

研究设计与样本

  • 85例经组织学证实的前列腺癌患者行3T双参数MRI(T2WI、DWI),其中66例另行3T T1 mapping;对肿瘤、外周带和移行带在三维MRI数据(T2WI、表观扩散系数、T1图)的多层面逐像素分割;图像经对比度、亮度、噪声和透视多次增强,样本量增至10倍,增强前后共提取322个放射组学特征;采用随机森林、随机梯度提升、支持向量机和k近邻四种机器学习算法,分别在有和无T1 mapping特征下训练,以区分Gleason 6、7和≥8三组。

诊断标准与关键数值

  • 支持向量机区分Gleason 6、7和≥8的准确率为0.92(95%CI 0.62-1.00),随机森林0.83(95%CI 0.52-0.98),随机梯度提升0.75(95%CI 0.43-0.95),k近邻0.50(95%CI 0.21-0.79)。

临床应用与阅片要点

  • 作者认为,当数据有限时,图像增强和定量T1 mapping特征可能有助于提高双参数MRI放射组学区分不同Gleason分组的准确率并降低泛化误差。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aims of this study were to discriminate among prostate cancers (PCa's) with Gleason scores 6, 7, and ≥8 on biparametric magnetic resonance imaging (bpMRI) of the prostate using radiomics and to evaluate the added value of image augmentation and quantitative T1 mapping.

MATERIALS AND METHODS: Eighty-five patients with subsequently histologically proven PCa underwent bpMRI at 3 T (T2-weighted imaging, diffusion-weighted imaging) with 66 patients undergoing additional T1 mapping at 3 T. The PCa lesions as well as the peripheral and transition zones were segmented pixel by pixel in multiple slices of the 3D MRI data sets (T2-weighted images, apparent diffusion coefficient, and T1 maps). To increase the size of the data set, images were augmented for contrast, brightness, noise, and perspective multiple times, effectively increasing the sample size 10-fold, and 322 different radiomics features were extracted before and after augmentation. Four different machine learning algorithms, including a random forest (RF), stochastic gradient boosting (SGB), support vector machine (SVM), and k-nearest neighbor, were trained with and without features from T1 maps to differentiate among 3 different Gleason groups (6, 7, and ≥8).

RESULTS: Support vector machine showed the highest accuracy of 0.92 (95% confidence interval [CI], 0.62-1.00) for classifying the different Gleason scores, followed by RF (0.83; 95% CI, 0.52-0.98), SGB (0.75; 95% CI, 0.43-0.95), and k-nearest neighbor (0.50; 95% CI, 0.21-0.79). Image augmentation resulted in an average increase in accuracy between 0.08 (SGB) and 0.48 (SVM). Removing T1 mapping features led to a decline in accuracy for RF (-0.16) and SGB (-0.25) and a higher generalization error.

CONCLUSIONS: When data are limited, image augmentations and features from quantitative T1 mapping sequences might help to achieve higher accuracy and lower generalization error for classification among different Gleason groups in bpMRI by using radiomics.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Makowski MR, Bressem KK, Franz L, et al. De Novo Radiomics Approach Using Image Augmentation and Features From T1 Mapping to Predict Gleason Scores in Prostate Cancer. Invest Radiol. 2021. PMID: 34047538. doi:10.1097/RLI.0000000000000788

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。