文献速递腹部泌尿生殖CT

双源CT双能量视野深度学习扩展评估肾脏病变:一项回顾性初步研究

Evaluating renal lesions using deep-learning based extension of dual-energy FoV in dual-source CT-A retrospective pilot study.
PubMed 文献 · Eur J Radiol · 2021-04-24

本研究训练深度学习算法(DEEDL)以扩展双源CT双能量视野,在128例已知肾脏病变患者中模拟较小视野并评估重建效果;病变衰减值均方根误差为10.59 HU,虚拟平扫为15.7 HU,数据集间线性回归r²在衰减为0.89、虚拟平扫为0.63、碘图为0.75,病变强化分类准确率为0.91。

要点

  • DEEDL算法可从受限数据重建全双能量视野,在较小视野未覆盖区域实现可靠HU值测量。
  • 肾脏病变衰减值均方根误差为10.59 HU,虚拟平扫为15.7 HU。
  • 病变强化分类准确率为0.91,数据集间线性回归r²衰减0.89、虚拟平扫0.63、碘图0.75。

核心结论

  • DEEDL算法可从受限数据重建全双能量视野,在较小视野未覆盖区域实现可靠HU值测量并评估肾脏病变。

研究设计与样本

  • 回顾性初步研究,DEEDL算法在50例患者DECT数据上训练(Somatom Flash,DE-FoV=33 cm),回顾性收集128例已知肾脏病变且位于DE-FoV内患者(100/140 kVp;参考数据集1),模拟较小DE-FoV=20 cm排除目标肾脏病变(数据集2)并应用DEEDL。

诊断标准与关键数值

  • 病变按Bosniak分级:Bosniak 1和2共125个,Bosniak 2F 6个,Bosniak 3 1个,Bosniak 4/(部分)实性32个;衰减值RMSE 10.59 HU,虚拟平扫RMSE 15.7 HU;数据集1与2线性回归r²:衰减0.89、虚拟平扫0.63、碘图0.75;病变强化分类准确率0.91。

临床应用与阅片要点

  • 作者认为DEEDL算法可从受限数据重建全双能量视野,在较小视野未覆盖区域实现可靠HU值测量并评估肾脏病变。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Dual-source (DS) CT, dual-energy (DE) field of view (FoV) is limited to the size of the smaller detector array. The purpose was to establish a deep learning-based approach to DE extrapolation by estimating missing image data using data from both tubes to evaluate renal lesions.

METHOD: A DE extrapolation deep-learning (DEEDL) algorithm had been trained on DECT data of 50 patients using a DSCT with DE-FoV = 33 cm (Somatom Flash). Data from 128 patients with known renal lesions falling within DE-FoV was retrospectively collected (100/140 kVp; reference dataset 1). A smaller DE-FoV = 20 cm was simulated excluding the renal lesion of interest (dataset 2) and the DEEDL was applied to this dataset. Output from the DEEDL algorithm was evaluated using ReconCT v14.1 and Syngo.via. Mean attenuation values in lesions on mixed images (HU) were compared calculating the root-mean-squared-error (RMSE) between the datasets using MATLAB R2019a.

RESULTS: The DEEDL algorithm performed well reproducing the image data of the kidney lesions (Bosniak 1 and 2: 125, Bosniak 2F: 6, Bosniak 3: 1 and Bosniak 4/(partially) solid: 32) with RSME values of 10.59 HU, 15.7 HU for attenuation, virtual non-contrast, respectively. The measurements performed in dataset 1 and 2 showed strong correlation with linear regression (r2: attenuation = 0.89, VNC = 0.63, iodine = 0.75), lesions were classified as enhancing with an accuracy of 0.91.

CONCLUSION: This DEEDL algorithm can be used to reconstruct a full dual-energy FoV from restricted data, enabling reliable HU value measurements in areas not covered by the smaller FoV and evaluation of renal lesions.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Schwartz FR, Clark DP, Ding Y, et al. Evaluating renal lesions using deep-learning based extension of dual-energy FoV in dual-source CT-A retrospective pilot study. Eur J Radiol. 2021. PMID: 33933837. doi:10.1016/j.ejrad.2021.109734

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。