计算机断层扫描参数变化下影像组学特征的区分能力与稳定性:基于3D打印体模的任务分析
研究利用基于真实患者数据制作的3D打印CT体模,评估86个影像组学特征在8种CT参数变化下的稳定性与区分能力。结果显示8种参数变化在平均78/86个特征上引起显著差异,但84%的单变量特征检验能成功区分4类肝组织,组织间差异总体大于参数变化引起的类内差异。
要点
- CT参数变化(重建算法、重建核、层厚、层间距)平均影响78/86个影像组学特征,特征稳定性需关注。
- 84%的单变量影像组学特征检验可成功且统计学显著地区分肝囊肿、血管瘤、转移瘤与正常肝组织。
- 组织类型间的影像组学特征差异通常大于CT参数变化引起的类内差异。
核心结论
- 不同肝组织类型间影像组学特征值的差异通常大于CT参数变化引起的类内差异。
研究设计与样本
- 基于真实患者数据制作不透射线3D打印CT体模,采用碘化钾溶液纸打印技术;手动标注正常肝组织与3种病灶(良性囊肿、血管瘤、转移瘤);评估86个影像组学特征在240个CT序列(8种重建算法、重建核、层厚、层间距参数变化)中的稳定性与区分能力;采用Wilcoxon符号秩检验进行参数组间及组织类别间两两比较。
诊断标准与关键数值
- 共进行19,264次特征稳定性检验和8,256次区分能力检验;8种CT参数变化两两比较平均在78/86个影像组学特征上存在统计学显著差异;84%的单变量影像组学特征检验成功且统计学显著地区分4类肝组织;86个特征按稳定性与区分能力检验成功次数累计和排序。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aims of this study were to determine the stability of radiomics features against computed tomography (CT) parameter variations and to study their discriminative power concerning tissue classification using a 3D-printed CT phantom based on real patient data.
MATERIALS AND METHODS: A radiopaque 3D phantom was developed using real patient data and a potassium iodide solution paper-printing technique. Normal liver tissue and 3 lesion types (benign cyst, hemangioma, and metastasis) were manually annotated in the phantom. The stability and discriminative power of 86 radiomics features were assessed in measurements taken from 240 CT series with 8 parameter variations of reconstruction algorithms, reconstruction kernels, slice thickness, and slice spacing. Pairwise parameter group and pairwise tissue class comparisons were performed using Wilcoxon signed rank tests.
RESULTS: In total, 19,264 feature stability tests and 8256 discriminative power tests were performed. The 8 CT parameter variation pairwise group comparisons had statistically significant differences on average in 78/86 radiomics features. On the other hand, 84% of the univariate radiomics feature tests had a successful and statistically significant differentiation of the 4 classes of liver tissue. The 86 radiomics features were ranked according to the cumulative sum of successful stability and discriminative power tests.
CONCLUSIONS: The differences in radiomics feature values obtained from different types of liver tissue are generally greater than the intraclass differences resulting from CT parameter variations.