Phase2Phase:无需真实标签的深度学习自由呼吸MRI呼吸运动分辨重建改善肝脏成像
本研究回顾性纳入33名参与者(15名健康人,18名肝癌患者),采用径向采集的自由呼吸MRI,将k空间数据分箱为10个呼吸相位,并模拟短采集(16%奈奎斯特采样率)重建图像,比较MCNUFFT、压缩感知(CS)、UNet3DPhase和Phase2Phase(P2P)四种方法。两位放射科医生盲法评估显示,UNet3DPhase和P2P图像的对比度更高、伪影更少(P<0.01),且P2P无需高质量真实标签训练;P2P的运动矢量长度与全采样MCNUFFT相当,而CS和UNet3DPhase则人为缩小了呼吸运动范围。
要点
- P2P无需真实标签即可从高度欠采样数据重建清晰、无伪影、高对比度的呼吸运动分辨图像。
- 与CS和UNet3DPhase相比,P2P不会人为缩小呼吸运动范围,更真实反映呼吸运动。
- UNet3DPhase伪影少于P2P,但需要高质量真实标签训练,临床推广受限。
关键影像表现/征象
- UNet3DPhase和P2P图像的对比度高于CS图像(P<0.01)。
- UNet3DPhase和P2P图像的伪影少于CS图像(P<0.01)。
- 一位评估者认为UNet3DPhase和P2P图像比CS更清晰(P<0.01),另一位评估者未发现差异(P=0.22,P=0.18)。
- UNet3DPhase和P2P在清晰度和对比度上相似,但UNet3DPhase伪影更少(P<0.01)。
- P2P800的运动矢量长度(9.9±4.0 mm)与MCNUFFT800(10.5±4.2 mm)相当,且均显著大于CS2000(7.0±3.9 mm)和UNet3DPhase800(6.9±3.2 mm)(P<0.0001)。
诊断标准与关键数值
- 图像质量主观评分包括清晰度、对比度和无伪影程度,由两位盲法放射科医生独立评估。
- 运动矢量长度用于评估呼吸运动范围,P2P800为9.9±4.0 mm,MCNUFFT800为10.5±4.2 mm,CS2000为7.0±3.9 mm,UNet3DPhase800为6.9±3.2 mm。
临床应用与阅片要点
- P2P可用于自由呼吸肝脏MRI,无需高质量真实标签训练,有望临床推广。
- 阅片时注意CS和UNet3DPhase可能低估呼吸运动幅度,P2P能更真实反映运动。
- P2P重建图像清晰、伪影少,但伪影略多于UNet3DPhase,需结合临床判断。
局限性
- 回顾性研究,样本量较小(33例)。
- 仅评估了呼气末图像,未评估其他呼吸相位。
- 未与临床常规图像直接比较诊断性能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Respiratory binning of free-breathing magnetic resonance imaging data reduces motion blurring; however, it exacerbates noise and introduces severe artifacts due to undersampling. Deep neural networks can remove artifacts and noise but usually require high-quality ground truth images for training. This study aimed to develop a network that can be trained without this requirement.
MATERIALS AND METHODS: This retrospective study was conducted on 33 participants enrolled between November 2016 and June 2019. Free-breathing magnetic resonance imaging was performed using a radial acquisition. Self-navigation was used to bin the k-space data into 10 respiratory phases. To simulate short acquisitions, subsets of radial spokes were used in reconstructing images with multicoil nonuniform fast Fourier transform (MCNUFFT), compressed sensing (CS), and 2 deep learning methods: UNet3DPhase and Phase2Phase (P2P). UNet3DPhase was trained using a high-quality ground truth, whereas P2P was trained using noisy images with streaking artifacts. Two radiologists blinded to the reconstruction methods independently reviewed the sharpness, contrast, and artifact-freeness of the end-expiration images reconstructed from data collected at 16% of the Nyquist sampling rate. The generalized estimating equation method was used for statistical comparison. Motion vector fields were derived to examine the respiratory motion range of 4-dimensional images reconstructed using different methods.
RESULTS: A total of 15 healthy participants and 18 patients with hepatic malignancy (50 ± 15 years, 6 women) were enrolled. Both reviewers found that the UNet3DPhase and P2P images had higher contrast (P < 0.01) and fewer artifacts (P < 0.01) than the CS images. The UNet3DPhase and P2P images were reported to be sharper than the CS images by 1 reviewer (P < 0.01) but not by the other reviewer (P = 0.22, P = 0.18). UNet3DPhase and P2P were similar in sharpness and contrast, whereas UNet3DPhase had fewer artifacts (P < 0.01). The motion vector lengths for the MCNUFFT800 and P2P800 images were comparable (10.5 ± 4.2 mm and 9.9 ± 4.0 mm, respectively), whereas both were significantly larger than CS2000 (7.0 ± 3.9 mm; P < 0.0001) and UNnet3DPhase800 (6.9 ± 3.2; P < 0.0001) images.
CONCLUSIONS: Without a ground truth, P2P can reconstruct sharp, artifact-free, and high-contrast respiratory motion-resolved images from highly undersampled data. Unlike the CS and UNet3DPhase methods, P2P did not artificially reduce the respiratory motion range.
引用
- Eldeniz C, Gan W, Chen S, et al. Phase2Phase: Respiratory Motion-Resolved Reconstruction of Free-Breathing Magnetic Resonance Imaging Using Deep Learning Without a Ground Truth for Improved Liver Imaging. Invest Radiol. 2021. PMID: 34038064. doi:10.1097/RLI.0000000000000792
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。