文献速递腹部CT

深度学习图像重建用于胰腺低剂量CT:与混合迭代重建的对比

Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction.
PubMed 文献 · Abdom Radiol (NY) · 2021-05-11

DLIR-H在图像噪声、诊断可接受性及PDAC显示清晰度上均显著优于混合迭代重建和DLIR-M(均P<0.001),并显著提高SNR和CNR。

要点

  • DLIR-H可显著降低胰腺LDCT图像噪声并提升PDAC病灶清晰度。
  • DLIR-H在图像质量主观评分及客观SNR/CNR上均优于混合迭代重建。

关键影像表现/征象

  • DLIR-H图像噪声、诊断可接受性及PDAC显示清晰度主观评分显著优于混合迭代重建和DLIR-M(均P<0.001)。
  • DLIR-H背景噪声显著更低(P<0.001),解剖结构SNR和肿瘤-胰腺CNR显著更高(均P<0.001)。

诊断标准与关键数值

  • 主观评估采用5分制,评价图像噪声、诊断可接受性和PDAC显示清晰度。
  • 定量参数包括腹主动脉、门静脉、胰腺、PDAC的CT值、背景噪声、SNR及肿瘤-胰腺CNR。

临床应用与阅片要点

  • 在胰腺低剂量CT中可优先选用DLIR-H重建,以降低噪声并提高PDAC病灶对比度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate image quality, image noise, and conspicuity of pancreatic ductal adenocarcinoma (PDAC) in pancreatic low-dose computed tomography (LDCT) reconstructed using deep learning image reconstruction (DLIR) and compare with those of images reconstructed using hybrid iterative reconstruction (IR).

METHODS: Our institutional review board approved this prospective study. Written informed consent was obtained from all patients. Twenty-eight consecutive patients with PDAC undergoing chemotherapy (14 men and 14 women; mean age, 68.4 years) underwent pancreatic LDCT for therapy evaluation. The LDCT images were reconstructed using 40% adaptive statistical iterative reconstruction-Veo (hybrid-IR) and DLIR at medium and high levels (DLIR-M and DLIR-H). The image noise, diagnostic acceptability, and conspicuity of PDAC were qualitatively assessed using a 5-point scale. CT numbers of the abdominal aorta, portal vein, pancreas, PDAC, background noise, signal-to-noise ratio (SNR) of the anatomical structures, and tumor-to-pancreas contrast-to-noise ratio (CNR) were calculated. Qualitative and quantitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H images.

RESULTS: CT dose-index volumes and dose-length product in pancreatic LDCT were 2.3 ± 1.0 mGy and 74.9 ± 37.0 mGy•cm, respectively. The image noise, diagnostic acceptability, and conspicuity of PDAC were significantly better in DLIR-H than those in hybrid-IR and DLIR-M (all P < 0.001). The background noise was significantly lower in the DLIR-H images (P < 0.001) and resulted in improved SNRs (P < 0.001) and CNR (P < 0.001) compared with those in the hybrid-IR and DLIR-M images.

CONCLUSION: DLIR significantly reduced image noise and improved image quality in pancreatic LDCT images compared with hybrid-IR.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Noda Y, Iritani Y, Kawai N, et al. Deep learning image reconstruction for pancreatic low-dose computed tomography: comparison with hybrid iterative reconstruction. Abdom Radiol (NY). 2021. PMID: 33973060. doi:10.1007/s00261-021-03111-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。