四种介入放射学操作的辐射剂量与诊断参考水平:欧洲多中心前瞻性调查EUCLID结果
剂量在医院内、医院间及各复杂度亚组内变异很大;使用先进设备使剂量显著降低52%;肝细胞癌TACE和经皮肝穿刺胆道引流中剂量与复杂度显著相关。
要点
- 按临床适应证定义的DRL可作为本地实践比较的基线。
- 使用先进血管造影设备可显著降低辐射剂量52%。
- TACE和PTBD中剂量与操作复杂度显著相关。
局限性
- 剂量值在医院内、医院间及复杂度亚组内变异很大,DRL的普适性需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess information reflecting radiation dose and define diagnostic reference levels (DRL) on a European basis for four interventional radiology (IR) procedures considering clinical indication, anatomical region, and procedure.
METHODS: A prospective European study was performed to provide data on the IR procedures percutaneous recanalization of iliac arteries, percutaneous recanalization of femoropopliteal arteries, transarterial chemoembolization of hepatocellular carcinoma, and percutaneous transhepatic biliary drainage. Hospitals were asked to complete a questionnaire giving information on procedure, equipment, and protocol. Patient size and weight, experience of the operator graded in number of procedures performed, and complexity level of each procedure were reported. Sixteen hospitals from 13 countries could be surveyed. The percentiles of the kerma-area product, fluoroscopy time, cumulative air kerma at the interventional reference point, and number of images were determined. The impact of equipment, year of installation, and complexity level of the procedure on dose were analyzed.
RESULTS: DRLs based on clinical indication were defined. Dose values varied considerably within hospitals, between them, and within each subgroup of complexity level. The use of state-of-the-art equipment reduced dose significantly by 52%. Although dose also varied within each subgroup of complexity level, for transarterial chemoembolization of hepatocellular carcinoma and percutaneous transhepatic biliary drainage, dose significantly correlated with complexity.
CONCLUSIONS: This was the first study reporting exposure practice and defining DRLs based on clinical indication for four IR procedures on a European basis. These DRLs can serve as a baseline for comparison with local practice, the study as a guideline for future surveys.
KEY POINTS: • The use of state-of-the-art angiographic equipment reduces dose significantly. • A significant correlation between radiation dose and complexity level is found. • Dose values vary considerably, both within and between individual hospitals, and within each complexity level of interventional radiology procedure.
引用
- Schegerer AA, Frija G, Paulo G, et al. Radiation dose and diagnostic reference levels for four interventional radiology procedures: results of the prospective European multicenter survey EUCLID. Eur Radiol. 2021. PMID: 33991223. doi:10.1007/s00330-021-08029-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。