文献速递腹部CT

CT量化正常胰腺表面分叶的可行性研究

Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas.
PubMed 文献 · Korean J Radiol · 2021-04-23

回顾性纳入265例无胰腺疾病患者,采用专用软件在增强腹部CT上由两名腹部放射科医生进行最多11次胰腺表面分叶(PSL)测量。结果显示PSL量化成功率高(81%)、读者间一致性优秀(ICC 0.82),且PSL随性别、年龄和BMI显著变化,为后续研究提供参考。

要点

  • 正常胰腺PSL平均值为6.53±1.37,男性显著高于女性。
  • PSL随年龄和BMI增加而逐渐升高(r均为0.32)。
  • PSL量化读者间一致性优秀(ICC 0.82),偏倚小。

核心结论

  • CT-based PSL量化在无胰腺疾病人群中可行,成功率高且读者间一致性优秀。
  • PSL在性别、年龄和BMI间存在显著差异,本研究为未来研究提供参考。

研究设计与样本

  • 回顾性研究,纳入2017-2019年间接受增强腹部CT的无胰腺疾病患者265例。
  • 由两名腹部放射科医生使用专用软件进行最多11次PSL测量(头部5次、体部3次、尾部3次)。
  • 采用Pearson相关和重复测量评估年龄、BMI和性别对PSL的影响,以ICC和Bland-Altman图评估读者间一致性。

诊断标准与关键数值

  • PSL均值±标准差为6.53±1.37。
  • 男性PSL均值显著高于女性(6.89±1.30 vs. 6.06±1.31,p<0.001)。
  • PSL与年龄(r=0.32,p<0.001)和BMI(r=0.32,p<0.001)呈正相关。
  • 读者间一致性ICC为0.82(95%CI 0.72-0.85),Bland-Altman偏倚0.30,95%一致性界限-1.29至1.89。

临床应用与阅片要点

  • 在无胰腺疾病人群中,PSL量化成功率高(81%),头部、体部、尾部测量成功率分别为76%、81%、90%。
  • 阅片时需注意PSL随性别、年龄和BMI变化,男性、高龄和高BMI者PSL可能更高。

局限性

  • 回顾性研究设计。
  • 6%的患者CT图像无法分析。
  • 测量成功率在胰腺头部较低(76%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the feasibility and reproducibility of pancreatic surface lobularity (PSL) quantification derived from abdominal computed tomography (CT) in a population of patients free from pancreatic disease.

MATERIALS AND METHODS: This retrospective study included 265 patients free from pancreatic disease who underwent contrast-enhanced abdominal CT between 2017 and 2019. A maximum of 11 individual PSL measurements were performed by two abdominal radiologists (head [5 measurements], body, and tail [3 measurements each]) using dedicated software. The influence of age, body mass index (BMI), and sex on PSL was assessed using the Pearson correlation and repeated measurements. Inter-reader agreement was assessed using the intraclass correlation coefficient (ICC) and Bland Altman (BA) plots.

RESULTS: CT images of 15 (6%) patients could not be analyzed. A total of 2750 measurements were performed in the remaining 250 patients (143 male [57%], mean age 45 years [range, 18-91]), and 2237 (81%) values were obtained in the head 951/1250 (76%), body 609/750 (81%), and tail 677/750 (90%). The mean ± standard deviation PSL was 6.53 ± 1.37. The mean PSL was significantly higher in male than in female (6.89 ± 1.30 vs. 6.06 ± 1.31, respectively, p < 0.001). PSL gradually increased with age (r = 0.32, p < 0.001) and BMI (r = 0.32, p < 0.001). Inter-reader agreement was excellent (ICC 0.82 [95% confidence interval 0.72-0.85], with a BA bias of 0.30 and 95% limits of agreement of -1.29 and 1.89).

CONCLUSION: CT-based PSL quantification is feasible with a high success rate and inter-reader agreement in subjects free from pancreatic disease. Significant variations were observed according to sex, age, and BMI. This study provides a reference for future studies.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Sartoris R, Calandra A, Lee KJ, et al. Quantification of Pancreas Surface Lobularity on CT: A Feasibility Study in the Normal Pancreas. Korean J Radiol. 2021. PMID: 33938646. doi:10.3348/kjr.2020.1049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。