文献速递腹部MR

CAIPIRINHA-VIBE联合MOCO在肝脏磁共振检查中的应用价值

Application value of CAIPIRINHA-VIBE with MOCO in liver magnetic resonance examination.
PubMed 文献 · Eur J Radiol · 2021-04-28

本研究纳入85例患者,比较CAIPIRINHA-VIBE与GRAPPA-VIBE在肝脏磁共振平扫蒙片期的图像质量,并评估非刚性三维配准运动校正(MOCO)联合CAIPIRINHA-VIBE对肝脏空间位置配准的效果。结果显示CAIPIRINHA-VIBE在呼吸运动伪影抑制、肝脏边缘锐利度和肝内血管锐利度方面评分显著高于GRAPPA-VIBE(p<0.05),且MOCO校正后肝脏空间位置一致性显著优于未校正。结论认为CAIPIRINHA-VIBE联合MOCO可替代常规GRAPPA-VIBE用于上腹部MRI增强检查,尤其适用于屏气不佳患者。

要点

  • CAIPIRINHA-VIBE在呼吸运动伪影抑制和肝内血管锐利度上优于GRAPPA-VIBE。
  • MOCO可显著改善CAIPIRINHA-VIBE多期扫描间肝脏空间位置的一致性。
  • 对屏气不佳患者,可优先选择CAIPIRINHA-VIBE联合MOCO进行上腹部增强MRI。

核心结论

  • CAIPIRINHA-VIBE联合MOCO可替代常规GRAPPA-VIBE用于上腹部MRI增强检查,尤其适用于屏气不佳患者。

研究设计与样本

  • 前瞻性自身对照研究,纳入85例患者,均行蒙片期GRAPPA-VIBE和CAIPIRINHA-VIBE屏气扫描,增强后行动脉期、门静脉期和延迟期CAIPIRINHA-VIBE屏气扫描。
  • 每期CAIPIRINHA-VIBE扫描完成后自动生成无MOCO和有MOCO的三维图像,由两名医师对蒙片期无MOCO的GRAPPA-VIBE和CAIPIRINHA-VIBE图像质量进行主观评分。
  • 以动脉期膈顶层面数为基准,计算其他期相与基准层面的差值,统计CAIPIRINHA无MOCO和有MOCO时各期膈肌运动范围(+N/-N)。

关键影像表现/征象

  • CAIPIRINHA-VIBE在呼吸运动伪影抑制、肝脏边缘锐利度和肝内血管锐利度方面的图像质量评分显著高于GRAPPA-VIBE(p<0.05)。
  • MOCO校正后肝脏空间位置一致性显著优于未校正的CAIPIRINHA-VIBE。

临床应用与阅片要点

  • 日常上腹部增强MRI可选用CAIPIRINHA-VIBE序列,以提高图像锐利度和运动伪影抑制效果。
  • 对屏气配合不佳的患者,建议联合MOCO以改善多期扫描间肝脏空间位置的一致性,便于对比增强各期病灶定位。

局限性

  • 单中心研究,样本量85例,结论外推需谨慎。
  • 仅比较了CAIPIRINHA-VIBE与GRAPPA-VIBE,未涉及其他加速序列或校正方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the image quality of VIBE sequence using controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA-VIBE) and using generalized autocalibrating partially parallel acquisitions (GRAPPA-VIBE) in liver magnetic resonance examination, and to evaluate the effect of non-rigid 3D-registration motion correction (MOCO) combined with CAIPIRINHA-VIBE on liver spatial location registration.

METHODS: A total of 85 patients underwent pre-contrast GRAPPA-VIBE and CAIPIRINHA-VIBE breath-hold scan in the mask phase, and then underwent CAIPIRINHA-VIBE breath-hold scan in arterial phase, portal vein phase and delay phase after administration. After the scanning of four phases of CAIPIRINHA-VIBE completed, 3D images without and with MOCO of each phase were automatically generated. The images quality of GRAPPA-VIBE and CAIPIRINHA-VIBE without MOCO in the mask phase was scored subjectively by two physicians. The number of slices at the top of the diaphragm in the arterial phase was taken as the base slice, and that in the other stages subtracted with the base slice for CAIPIRINHA without and with MOCO. The range of diaphragm movement in each phase was counted by + N/- N statistics.

RESULTS: The image quality and the scores of CAIPIRINHA-VIBE were significantly higher than those of GRAPPA-VIBE in respiratory motion artifact suppression, liver edge sharpness and intrahepatic vascular sharpness (p < 0.05). The spatial position consistency of the liver with MOCO is significantly better than that without MOCO.

CONCLUSION: CAIPIRINHA-VIBE with MOCO can be used instead of conventional GRAPPA-VIBE sequence in upper abdominal MRI enhancement examination, especially for patients with poor breath-hold.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Hu J, Xu B, Cao J, et al. Application value of CAIPIRINHA-VIBE with MOCO in liver magnetic resonance examination. Eur J Radiol. 2021. PMID: 33945922. doi:10.1016/j.ejrad.2021.109739

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。