文献速递腹部MR

胰腺磁共振成像影像组学能否预测术后胰瘘?

Can magnetic resonance imaging radiomics of the pancreas predict postoperative pancreatic fistula?
PubMed 文献 · Eur J Radiol · 2021-04-24

回顾性分析62例胰十二指肠切除术前接受3 T MRI的患者,提取173个影像组学特征并测量胰腺-肌肉T1信号强度比,构建梯度提升树与逻辑回归模型预测临床相关术后胰瘘(CR-POPF);联合影像组学与T1信号强度比的梯度提升树模型AUC达0.90(95%CI 0.84-0.95)。

要点

  • 联合影像组学特征与T1信号强度比的梯度提升树模型预测CR-POPF的AUC为0.90(95%CI 0.84-0.95)。
  • 仅用影像组学特征的梯度提升树模型在原始数据集上AUC为0.82(95%CI 0.74-0.89)。
  • 仅用T1信号强度比时,梯度提升树与逻辑回归模型的AUC均为0.75(95%CI 0.63-0.84)。

核心结论

  • 基于常规序列的MRI影像组学对临床相关术后胰瘘(CR-POPF)显示出有前景的预测价值。

研究设计与样本

  • 回顾性分析2008年至2018年间62例胰十二指肠切除术前接受3 T MRI的患者,在T1和T2加权图像上于胰体及胰尾放置2个感兴趣区,用pyRadiomics提取173个影像组学特征并测量胰腺-肌肉T1信号强度比,数据集经增强后按70%训练集、30%测试集拆分,用Boruta算法降维,以梯度提升树和逻辑回归构建模型预测CR-POPF。

诊断标准与关键数值

  • 识别出预测CR-POPF最重要的5个影像组学特征;基于这些特征的梯度提升树在原始(非增强)数据集上AUC为0.82(95%CI 0.74-0.89);T1信号强度比的梯度提升树模型AUC为0.75(95%CI 0.63-0.84),逻辑回归模型AUC为0.75(95%CI 0.63-0.84);联合影像组学特征与T1信号强度比的梯度提升树模型AUC为0.90(95%CI 0.84-0.95)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate whether a magnetic resonance imaging (MRI) radiomics-based machine learning classifier can predict postoperative pancreatic fistula (POPF) after pancreaticoduodenectomy (PD) and to compare its performance to T1 signal intensity ratio (T1 SIratio).

METHODS: Sixty-two patients who underwent 3 T MRI before PD between 2008 and 2018 were retrospectively analyzed. POPF was graded and split into clinically relevant POPF (CR-POPF) vs. biochemical leak or no POPF. On T1- and T2-weighted images, 2 regions of interest were placed in the pancreatic corpus and cauda. 173 radiomics features were extracted using pyRadiomics. Additionally, the pancreas-to-muscle T1 SIratio was measured. The dataset was augmented and split into training (70 %) and test sets (30 %). A Boruta algorithm was used for feature reduction. For prediction of CR-POPF models were built using a gradient-boosted tree (GBT) and logistic regression from the radiomics features, T1 SIratio and a combination of the two. Diagnostic accuracy of the models was compared using areas under the receiver operating characteristics curve (AUCs).

RESULTS: Five most important radiomics features were identified for prediction of CR-POPF. A GBT using these features achieved an AUC of 0.82 (95 % Confidence Interval [CI]: 0.74 - 0.89) when applied on the original (non-augmented) dataset. Using T1 SIratio, a GBT model resulted in an AUC of 0.75 (CI: 0.63 - 0.84) and a logistic regression model delivered an AUC of 0.75 (CI: 0.63 - 0.84). A GBT model combining radiomics features and T1 SIratio resulted in an AUC of 0.90 (CI 0.84 - 0.95).

CONCLUSION: MRI-radiomics with routine sequences provides promising prediction of CR-POPF.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Skawran SM, Kambakamba P, Baessler B, et al. Can magnetic resonance imaging radiomics of the pancreas predict postoperative pancreatic fistula? Eur J Radiol. 2021. PMID: 33945924. doi:10.1016/j.ejrad.2021.109733

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。