文献速递腹部介入USCT

电极位移弹性成像鉴别肝肿瘤微波消融前后影像

Differential Imaging of Liver Tumors before and after Microwave Ablation with Electrode Displacement Elastography.
PubMed 文献 · Ultrasound Med Biol · 2021-05-16

本研究纳入13例肝细胞癌或肝转移患者,采用电极位移弹性成像(EDE)在微波消融前后对肿瘤和消融区进行成像。结果显示估计消融边缘四分位距为0.54-1.21 cm、中位值0.84 cm,处于或高于目标消融边缘范围;EDE应变图像与增强CT分割横截面积高度相关(消融前r2=0.97,消融后r2=0.98),提示EDE有潜力在临床消融中区分靶肿瘤与消融区。

要点

  • EDE可同时显示消融前肿瘤和消融后区域,与增强CT分割面积高度相关。
  • 估计消融边缘中位值0.84 cm,位于或高于常规目标消融边缘范围。
  • 常规B超和CT在消融引导中有局限,弹性成像可作为补充手段。

核心结论

  • EDE在微波消融前后对肝肿瘤和消融区成像可行,估计消融边缘与目标范围相符,且与增强CT分割面积高度相关,有潜力用于临床消融中区分靶肿瘤与消融区。

研究设计与样本

  • 单中心研究,纳入13例肝细胞癌或肝转移患者,采用电极位移弹性成像(EDE)在微波消融前后成像,以增强CT为当前临床金标准进行分割面积对比。

关键影像表现/征象

  • EDE可显示消融前肿瘤和消融后区域,应变图像与增强CT对应分割横截面积高度相关(消融前r2=0.97,消融后r2=0.98)。

诊断标准与关键数值

  • 常规微波消融目标消融边缘为0.5-1.0 cm,与疗效强相关;本研究EDE估计消融边缘四分位距0.54-1.21 cm、中位值0.84 cm。
  • EDE应变图像与增强CT分割横截面积相关性:消融前r2=0.97,消融后r2=0.98。

临床应用与阅片要点

  • 阅片时可关注EDE显示的消融边缘是否达到0.5-1.0 cm目标范围,并与增强CT对应层面分割面积对照。
  • EDE对消融前肿瘤可视化受癌种间应变对比变异性限制,判读时需结合常规影像。

局限性

  • 样本量仅13例,为单中心研究,结论需更大样本验证。
  • 原文指出消融前可视化受癌种间应变对比变异性限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Liver cancer is a leading cause of cancer-related deaths; however, primary treatment options such as surgical resection and liver transplant may not be viable for many patients. Minimally invasive image-guided microwave ablation (MWA) provides a locally effective treatment option for these patients with an impact comparable to that of surgery for both cancer-specific and overall survival. MWA efficacy is correlated with accurate image guidance; however, conventional modalities such as B-mode ultrasound and computed tomography have limitations. Alternatively, ultrasound elastography has been used to demarcate post-ablation zones, yet has limitations for pre-ablation visualization because of variability in strain contrast between cancer types. This study attempted to characterize both pre-ablation tumors and post-ablation zones using electrode displacement elastography (EDE) for 13 patients with hepatocellular carcinoma or liver metastasis. Typically, MWA ablation margins of 0.5-1.0 cm are desired, which are strongly correlated with treatment efficacy. Our results revealed an average estimated ablation margin inner quartile range of 0.54-1.21 cm with a median value of 0.84 cm. These treatment margins lie within or above the targeted ablative margin, indicating the potential to use EDE for differentiating index tumors and ablated zones during clinical ablations. We also obtained a high correlation between corresponding segmented cross-sectional areas from contrast-enhanced computed tomography, the current clinical gold standard, when compared with EDE strain images, with r2 values of 0.97 and 0.98 for pre- and post-ablation regions.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Pohlman RM, Hinshaw JL, Ziemlewicz TJ, et al. Differential Imaging of Liver Tumors before and after Microwave Ablation with Electrode Displacement Elastography. Ultrasound Med Biol. 2021. PMID: 34011451. doi:10.1016/j.ultrasmedbio.2021.03.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。