文献速递心血管外周血管MR

非功能异常二叶式主动脉瓣的瓣叶融合长度与主动脉扩张及血流改变相关

Leaflet fusion length is associated with aortic dilation and flow alterations in non-dysfunctional bicuspid aortic valve.
PubMed 文献 · Eur Radiol · 2021-05-12

本研究前瞻性纳入120例无显著瓣膜功能障碍的二叶式主动脉瓣患者,采用心脏磁共振4D flow序列评估血流动力学,并用双斜位cine图像测量瓣叶融合长度。结果显示融合长度可可靠测量(ICC=0.826),且独立关联于Valsalva窦和升主动脉直径及z-score,并与血流不对称、涡流和环向壁剪切应力正相关,提示融合长度可能提供主动脉扩张的病理生理链接。

要点

  • 非功能异常二叶式主动脉瓣的瓣叶融合长度变异大, cine CMR可可靠测量。
  • 融合长度独立关联于Valsalva窦和升主动脉直径及z-score。
  • 融合长度与血流不对称、涡流及环向壁剪切应力正相关。

关键影像表现/征象

  • 主动脉瓣叶融合在112/120例(93%)中可测量,可重复性好(ICC=0.826)。
  • 融合长度变异大(范围2.3-15.4 mm;均值7.8±3.2 mm)。
  • 融合长度与血流不对称、涡流和环向壁剪切应力正相关。

诊断标准与关键数值

  • 融合长度独立关联于Valsalva窦直径(p=0.002)和z-score(p=0.002)。
  • 融合长度独立关联于升主动脉直径(p=0.028)和z-score(p=0.046)。

临床应用与阅片要点

  • 在二叶式主动脉瓣患者中,应关注瓣叶融合长度,其与主动脉扩张和血流异常相关。
  • cine CMR可用于可靠测量融合长度,辅助风险评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Bicuspid aortic valve (BAV), the most common congenital valve defect, is associated with increased risk of aortic dilation and related complications; however, current risk assessment is not effective. Most of BAV have three leaflets with a fusion between two of them of variable length. This study aimed to ascertain whether the extent of leaflet fusion (often called raphe) is related to aortic dilation and flow abnormalities in BAV with no significant valvular dysfunction.

METHODS: One hundred and twenty BAV patients with no significant valvular dysfunction or history of surgical repair or aortic valve replacement were consecutively and prospectively enrolled (September 2014-October 2018). Cardiac magnetic resonance protocol included a 4D flow sequence for haemodynamic assessment. Moreover, a stack of double-oblique cine images of the aortic valve were used to quantify fusion length (in systole) and leaflet length (diastole). Inter- and intra-observer reproducibility was tested in 30 randomly selected patients.

RESULTS: Aortic valve leaflet fusion was measurable in 112 of 120 (93%) cases with good reproducibility (ICC = 0.826). Fusion length varied greatly (range: 2.3-15.4 mm; mean: 7.8 ± 3.2 mm). After correction for demographic and clinical conditions, fusion length was independently associated with diameter and z-score at the sinus of Valsalva (p = 0.002 and p = 0.002, respectively) and ascending aorta (p = 0.028 and p = 0.046). Fusion length was positively related to flow asymmetry, vortices and circumferential wall shear stress, thereby possibly providing a pathophysiological link with aortic dilation.

CONCLUSIONS: Aortic valve fusion length is related to aortic dilation and flow abnormalities in BAV patients.

KEY POINTS: • The length of the fusion between leaflets in non-dysfunctional bicuspid aortic valves varies substantially and can be reliably measured by cine CMR. • Aortic valve leaflet fusion length is independently related to aortic sinus and ascending aorta diameter. • Increased flow asymmetry, circumferential wall shear stress and presence of vortices are positively related to aortic valve leaflet fusion length.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Guala A, Evangelista A, Teixido-Tura G, et al. Leaflet fusion length is associated with aortic dilation and flow alterations in non-dysfunctional bicuspid aortic valve. Eur Radiol. 2021. PMID: 33977309. doi:10.1007/s00330-021-08016-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。