20周胎儿二叶式主动脉瓣的心脏生物测量与血流评估:多中心队列研究

Prenatal cardiac biometry and flow assessment in fetuses with bicuspid aortic valve at 20 weeks' gestation: multicenter cohort study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-11-10

本研究基于哥本哈根婴儿心脏研究的多中心队列,比较了55例出生后确诊二叶式主动脉瓣(BAV)的胎儿与8316例心脏结构正常胎儿在孕20周时的超声心动图生物测量和血流参数。结果显示BAV胎儿主动脉瓣环水平和肺动脉瓣水平的直径显著较大,但经Z-score转换和Bonferroni校正后差异不再显著;BAV组母亲孕前吸烟比例和低PAPP-A MoM与BAV相关。

要点

  • BAV胎儿在20周时主动脉瓣环和肺动脉瓣水平直径较正常胎儿稍大,但校正后差异不显著。
  • 孕妇孕前吸烟和低PAPP-A MoM可能与胎儿BAV相关,提示产前筛查可关注这些因素。
  • 常规四腔心切面联合左室流出道和三血管切面测量有助于发现主动脉和肺动脉直径的细微变化。

诊断标准与关键数值

  • BAV组主动脉瓣水平直径平均差0.12 mm(95%CI 0.03-0.21 mm),肺动脉瓣水平直径平均差0.15 mm(95%CI 0.03-0.28 mm)。
  • 经Z-score转换和Bonferroni校正后,上述直径差异不再有统计学意义。

局限性

  • BAV组样本量较小(55例),可能影响统计效能。
  • 研究为观察性队列,无法确立因果关系。
  • 仅评估了20周左右的参数,未纵向随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate prenatal changes in cardiac biometric and flow parameters in fetuses with bicuspid aortic valve (BAV) diagnosed neonatally compared with controls with normal cardiac anatomy.

METHODS: This analysis was conducted as part of the Copenhagen Baby Heart Study, a multicenter cohort study of 25 556 neonates that underwent second-trimester anomaly scan at 18 + 0 to 22 + 6 weeks' gestation and neonatal echocardiography within 4 weeks after birth, in Copenhagen University Hospital Herlev, Hvidovre Hospital and Rigshospitalet in greater Copenhagen, between April 2016 and October 2018. From February 2017 (Rigshospitalet) and September 2017 (Herlev and Hvidovre hospitals), the protocol for second-trimester screening of the heart was extended to include evaluation of the four-chamber view, with assessment of flow across the atrioventricular valves, sagittal view of the aortic arch and midumbilical artery and ductus venosus pulsatility indices. All images were evaluated by two investigators, and cardiac biometric and flow parameters were measured and compared between cases with BAV and controls. All cases with neonatal BAV were assessed by a specialist. Maternal characteristics and first- and second-trimester biomarkers were also compared between the two groups.

RESULTS: Fifty-five infants with BAV and 8316 controls with normal cardiac anatomy were identified during the study period and assessed using the extended prenatal cardiac imaging protocol. There were three times as many mothers who smoked before pregnancy in the group with BAV as in the control group (9.1% vs 2.7%; P = 0.003). All other baseline characteristics were similar between the two groups. Fetuses with BAV, compared with controls, had a significantly larger diameter of the aorta at the level of the aortic valve (3.1 mm vs 3.0 mm (mean difference, 0.12 mm (95% CI, 0.03-0.21 mm))) and the pulmonary artery at the level of the pulmonary valve (4.1 mm vs 3.9 mm (mean difference, 0.15 mm (95% CI, 0.03-0.28 mm))). Following conversion of the diameter measurements of the aorta and pulmonary artery to Z-scores and Bonferroni correction, the differences between the two groups were no longer statistically significant. Pregnancy-associated plasma protein-A (PAPP-A) multiples of the median (MoM) was significantly lower in the BAV group than in the control group (0.85 vs 1.03; P = 0.04).

CONCLUSIONS: Our findings suggest that fetuses with BAV may have a larger aortic diameter at the level of the aortic valve, measured in the left-ventricular-outflow-tract view, and a larger pulmonary artery diameter at the level of the pulmonary valve, measured in the three-vessel view, at 20 weeks' gestation. Moreover, we found an association of maternal smoking and low PAPP-A MoM with BAV. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.