文献速递胸部介入CT

IPF患者CT引导经皮肺穿刺活检诊断恶性肿瘤的准确性与并发症

Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis.
PubMed 文献 · Eur Radiol · 2021-05-18

本回顾性研究纳入80例IPF患者的91次CT引导经皮肺穿刺活检,诊断准确率89%、敏感度90%、特异度84%,非诊断结果占34%。病灶≤3cm及针尖位于目标病灶外是非诊断结果的危险因素,针道穿过蜂窝肺是大并发症的独立危险因素,总体并发症率51%、主要并发症率12%。

要点

  • IPF患者PTNB诊断恶性肿瘤准确率尚可,但非诊断率高达34%,需警惕假阴性。
  • 病灶≤3cm或针尖未置于目标病灶内时非诊断风险显著增加。
  • 针道穿过蜂窝肺区域时主要并发症风险升高,总体并发症率可达51%。
英文原文(摘要)· 点击展开

OBJECTIVES: To determine the accuracy of CT-guided percutaneous transthoracic needle lung biopsy (PTNB) for the diagnosis of malignancy and the associated complication rates in patients with idiopathic pulmonary fibrosis (IPF).

METHODS: This retrospective study included 91 CT-guided PTNBs performed in 80 patients with IPF from April 2003 through December 2016. Data regarding patients, target lesions, procedures, complications, and pathological reports were collected, and the final diagnosis was made. The diagnostic accuracy, sensitivity, specificity, percentage of nondiagnostic results, and complication rates were determined. Multivariable logistic regression analyses were performed to identify risk factors for nondiagnostic results and major complications.

RESULTS: Three biopsies (technical failure [n = 2] and undetermined final diagnosis [n = 1]) were excluded from the diagnostic accuracy calculation. The diagnostic accuracy, sensitivity, and specificity were 89% (78/88), 90% (62/69), and 84% (16/19), respectively. The percentage of nondiagnostic results was 34% (30/88). Lesion size ≤ 3 cm (odds ratio [OR], 8.8; 95% confidence interval [CI], 2.5-31.2; p = 0.001) and needle tip placement outside the target lesion (OR, 13.7; 95% CI, 1.4-132.2; p = 0.02) were risk factors for nondiagnostic results. The overall and major complication rates were 51% (46/91) and 12% (11/91), respectively. The presence of honeycombing along the path of the needle (OR, 11.2; 95% CI, 1.4-89.1; p = 0.02) was an independent risk factor for major complications.

CONCLUSIONS: CT-guided PTNB shows a relatively reasonable accuracy in diagnosing malignancy in patients with IPF. The complication rate may be high, especially when the needle passes through honeycomb lesions.

KEY POINTS: • In patients with idiopathic pulmonary fibrosis (IPF), CT-guided percutaneous transthoracic needle lung biopsy (PTNB) showed a relatively reasonable accuracy for the diagnosis of malignancy. • Target lesion size ≤ 3 cm and biopsy needle tip placement outside the target lesion were risk factors for nondiagnostic results of CT-guided PTNB. • The complication rate may be high, especially in cases where the biopsy needle passes through honeycomb lesions.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Shin YJ, Yun G, Yoon SH, et al. Accuracy and complications of percutaneous transthoracic needle lung biopsy for the diagnosis of malignancy in patients with idiopathic pulmonary fibrosis. Eur Radiol. 2021. PMID: 34003347. doi:10.1007/s00330-021-08038-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。