文献速递胸部CT

人工智能辅助计算机辅助检测在多排CT肺结节识别中的性能与阅读时间比较

Performance and reading time of lung nodule identification on multidetector CT with or without an artificial intelligence-powered computer-aided detection system.
PubMed 文献 · Clin Radiol · 2021-05-19

结果显示二次阅读和同步阅读均提高敏感度,同步阅读时间最短,且两种CAD模式间敏感度、特异度和AUC无显著差异。

要点

  • 同步阅读模式可缩短阅片时间,同时保持与二次阅读相当的敏感度。
  • 使用CAD(二次或同步阅读)可将肺结节检测平均敏感度从64%提升至80%–82%。
  • junior和senior读者在两种CAD模式下的敏感度、特异度及AUC均无显著差异。

诊断标准与关键数值

  • 所有读者平均敏感度:无CAD模式64%(95%CI 62%–66%),二次阅读模式82%(95%CI 80%–84%),同步阅读模式80%(95%CI 79%–82%),p<0.001。
  • 二次阅读与同步阅读模式间平均敏感度、特异度和AUC均无显著差异(p>0.05)。
  • 所有读者阅读时间:同步阅读模式124±25秒,显著短于无CAD模式156±34秒(p<0.001)和二次阅读模式197±46秒(p<0.001)。

局限性

  • 回顾性研究设计。
  • 仅纳入直径≤10mm的结节,结果可能不适用于更大结节。
  • 样本来自单中心(原文未明确多中心)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To compare the performance and reading time of different readers using automatic artificial intelligence (AI)-powered computer-aided detection (CAD) to detect lung nodules in different reading modes.

MATERIALS AND METHODS: One hundred and fifty multidetector computed tomography (CT) datasets containing 340 nodules ≤10 mm in diameter were collected retrospectively. A CAD with vessel-suppressed function was used to interpret the images. Three junior and three senior readers were assigned to read (1) CT images without CAD, (2) second-read using CAD in which CAD was applied only after initial unassisted assessment, and (3) a concurrent read with CAD in which CAD was applied at the start of assessment. Diagnostic performances and reading times were compared using analysis of variance.

RESULTS: For all readers, the mean sensitivity improved from 64% (95% confidence interval [CI]: 62%, 66%) for the without-CAD mode to 82% (95% CI: 80%, 84%) for the second-reading mode and to 80% (95% CI: 79%, 82%) for the concurrent-reading mode (p<0.001). There was no significant difference between the two modes in terms of the mean sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for both junior and senior readers and all readers (p>0.05). The reading time of all readers was significantly shorter for the concurrent-reading mode (124 ± 25 seconds) compared to without CAD (156 ± 34 seconds; p<0.001) and the second-reading mode (197 ± 46 seconds; p<0.001).

CONCLUSION: In CAD for lung nodules at CT, the second-reading mode and concurrent-reading mode may improve detection performance for all readers in both screening and clinical routine practice. Concurrent use of CAD is more efficient for both junior and senior readers.