不同瘤周影像组学特征在鉴别表现为磨玻璃结节的腺癌浸润性中的价值
这项回顾性研究纳入121例薄层CT上表现为磨玻璃结节的肺腺癌,从瘤周2 mm和5 mm肺实质提取影像组学特征构建External2和External5模型,用于鉴别浸润性腺癌(IAC)与原位腺癌(AIS)/微浸润腺癌(MIA)。两个模型均表现出良好预测价值,训练队列AUC分别为0.882和0.778,验证队列分别为0.888和0.804,但2 mm与5 mm模型间AUC差异无统计学意义。
要点
- 瘤周2 mm影像组学模型可辅助鉴别IAC与AIS/MIA,训练和验证队列AUC均较高。
- 瘤周5 mm模型相对2 mm模型未提供额外鉴别增益,两者AUC差异无统计学意义。
- 阅片时可关注磨玻璃结节瘤周肺实质区域,其可能含有辅助判断浸润性的信息。
核心结论
- 薄层CT瘤周2 mm和5 mm区域提取的影像组学特征对鉴别IAC与AIS/MIA均具有良好预测价值。
- 瘤周5 mm影像组学特征在区分IAC与MIA/AIS方面较2 mm区域未提供额外获益。
研究设计与样本
- 回顾性研究,纳入121例薄层CT上表现为磨玻璃结节的肺腺癌。
- 从瘤周2 mm和5 mm肺实质区域提取定量影像组学特征,构建External2和External5模型。
- 采用ROC曲线评估模型性能,DeLong法比较AUC差异。
诊断标准与关键数值
- External2模型鉴别IAC与MIA/AIS的AUC在训练队列为0.882,验证队列为0.888。
- External5模型鉴别IAC与MIA/AIS的AUC在训练队列为0.778,验证队列为0.804。
- External2与External5模型AUC差异在训练队列p=0.116、验证队列p=0.423,均无统计学意义。
- IAC的影像组学评分在External2和External5模型中均统计学高于MIA/AIS。
临床应用与阅片要点
- 对表现为磨玻璃结节的肺腺癌,可关注瘤周肺实质影像组学信息辅助判断浸润性。
- 建模或报告时可优先选择瘤周2 mm区域,5 mm区域未显示额外鉴别价值。
- 鉴别IAC与AIS/MIA时,瘤周影像组学可作为结节本身特征之外的补充信息。
局限性
- 本研究为回顾性设计。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the ability of CT radiomic features extracted from peritumoral parenchyma of 2 mm and 5 mm distinguishing invasive adenocarcinoma (IAC) from adenocarcinoma in situ (AIS)/minimally invasive adenocarcinoma (MIA).
METHODS: For this retrospective study, 121 lung adenocarcinomas appearing as ground-glass nodules on thin-section CT were evaluated. Quantitative radiomic features were extracted from the peritumoral parenchymal region of 2 mm and 5 mm on CT imaging, and the radiomic models of External2 and External5 were constructed. The ROC curves were used to evaluate the performance of different models. Differences between the AUCs were evaluated using DeLong's method.
RESULTS: The radiomic scores of IAC were statistically higher than those of MIA/AIS in both the External2 and External5 models. The AUCs of the External2 and External5 models were 0.882, 0.778 in the training cohort and 0.888, 0.804 in the validation cohort, respectively. The AUC of the External2 model was not statistically different from the External5 model both in the training cohort (p = 0.116) and validation cohort (p = 0.423).
CONCLUSIONS: The radiomic features extracted from the peritumoral region of 2 mm and 5 mm at thin-section CT showed good predictive values to differentiate the IAC from AIS/MIA. The radiomic features from the peritumoral region of 5 mm provide no additional benefit in distinguishing IAC from MIA/AIS than that of the 2 mm region.
KEY POINTS: • The radiomic models from various peritumoral lung parenchyma were developed and validated to predict invasiveness of adenocarcinoma. • The peritumoral parenchyma of lung adenocarcinoma may contain useful information. • Radiomics from peritumoral lung parenchyma of 5 mm provides no added efficiency of the prediction for invasiveness of lung adenocarcinoma.
引用
- Wu L, Gao C, Ye J, et al. The value of various peritumoral radiomic features in differentiating the invasiveness of adenocarcinoma manifesting as ground-glass nodules. Eur Radiol. 2021. PMID: 34037830. doi:10.1007/s00330-021-07948-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。