文献速递胸部介入CT

锥形束CT引导经皮肺穿刺活检膈旁病灶的诊断准确性与并发症

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications.
PubMed 文献 · Korean J Radiol · 2021-04-09

本研究回顾性纳入336例膈旁肺病灶的锥形束CT引导经皮穿刺活检,诊断恶性肿瘤的准确率为92.7%,敏感度91.3%,特异度91.4%。病灶≤2 cm是诊断失败唯一显著风险因素,并发症发生率29.2%,主要风险因素包括高龄、病灶≤2 cm、肺气肿及胸膜至病灶距离>2 cm。

要点

  • 膈旁病灶穿刺活检诊断准确率较高(92.7%),但需注意病灶≤2 cm时诊断失败风险增加。
  • 并发症以气胸为主(26.5%),高龄、肺气肿、病灶小及穿刺距离远是并发症的独立风险因素。
  • 操作时应综合评估病灶大小、肺气肿及穿刺路径,以降低诊断失败和并发症风险。

核心结论

  • 锥形束CT引导经皮肺穿刺活检对膈旁病灶的诊断准确率较高,病灶大小是诊断失败的独立预测因素。
  • 并发症发生率在可接受范围内,高龄、病灶≤2 cm、肺气肿及胸膜至病灶距离>2 cm是并发症的显著风险因素。

研究设计与样本

  • 病灶平均大小4.3±2.3 cm,均毗邻膈肌;以恶性诊断准确性为主要终点,采用意向诊断原则计算诊断效能。
  • 采用logistic回归分析诊断失败和并发症的风险因素。

诊断标准与关键数值

  • 诊断恶性肿瘤的准确率92.7%(293/316),敏感度91.3%(219/240),特异度91.4%(74/81),阳性预测值96.9%(219/226),阴性预测值77.9%(74/95)。
  • 诊断失败率7.3%(23/336),病灶≤2 cm是诊断失败的独立风险因素(p=0.045)。
  • 并发症发生率29.2%(98/336),其中气胸26.5%(89/336),咯血2.1%(7/336)。
  • 并发症的独立风险因素包括年龄>65岁(p=0.002)、病灶≤2 cm(p=0.003)、肺气肿(p=0.006)及胸膜至病灶距离>2 cm(p=0.010)。

临床应用与阅片要点

  • 对于膈旁病灶,锥形束CT引导活检可作为获取病理诊断的有效手段,但术前应评估病灶大小、肺气肿及穿刺路径。
  • 病灶≤2 cm时诊断失败风险增加,可能需要更精确的穿刺技术或考虑重复活检。
  • 高龄、肺气肿及穿刺距离较远的患者并发症风险较高,应加强术中监测和术后随访。

局限性

  • 回顾性研究设计,可能存在选择偏倚。
  • 单中心研究,结果外推需谨慎。
  • 未报告操作者经验、针具型号等可能影响结果的因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications.

MATERIALS AND METHODS: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis.

RESULTS: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications.

CONCLUSION: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Hong W, Yoon SH, Goo JM, et al. Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications. Korean J Radiol. 2021. PMID: 33938644. doi:10.3348/kjr.2020.1229

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。