文献速递神经头颈MR

IDEAL-T2WI序列对甲状腺相关性眼病视神经病变的诊断价值:视神经及视神经鞘脑脊液的定量分析

The diagnostic value of the IDEAL-T2WI sequence in dysthyroid optic neuropathy: a quantitative analysis of the optic nerve and cerebrospinal fluid in the optic nerve sheath.
PubMed 文献 · Eur Radiol · 2021-05-15

单中心回顾性研究分析30例DON(54眼)、30例无DON的TAO(60眼)及19例健康对照(38眼)的眶部MRI,发现DON组视神经水分数及球后3 mm和6 mm处视神经鞘蛛网膜下腔(ONSS)均显著大于TAO组和HC组(p<0.01)。球后3 mm处ONSS预测DON的AUC为0.957,敏感度0.907,特异度0.9;球后3 mm处视神经水分数特异度最高(0.967)。

要点

  • DON组球后3 mm和6 mm处视神经直径、水分数及ONSS均显著大于TAO组和HC组(p<0.01)。
  • 球后3 mm处ONSS预测DON的AUC为0.957,敏感度0.907,特异度0.9。
  • 球后3 mm处视神经水分数特异度最高(0.967),且与临床活动度评分、平均缺损及模式标准差相关。

核心结论

  • 视神经水分数增高和球后3 mm处ONSS增大是诊断DON有前景且易于获取的影像学标志物。

研究设计与样本

  • 单中心回顾性研究,纳入30例DON(54眼)、30例无DON的TAO患者(60眼)和19例健康对照(38眼),分析眶部MRI的IDEAL-T2WI序列,测量视神经及鞘直径、截面积、视神经水分数和鞘内液体体积,并与临床指标做相关分析。

关键影像表现/征象

  • DON组球后3 mm和6 mm处视神经直径和水分数、ONSS及视神经鞘蛛网膜下腔液体体积均显著大于TAO组(p<0.01)和HC组(p<0.01)。
  • 球后3 mm处ONSS是DON的强预测指标(AUC=0.957,敏感度=0.907,特异度=0.9)。
  • 球后3 mm处视神经水分数特异度最高(0.967)。
  • 球后3 mm处视神经水分数、视神经鞘液体体积及球后3 mm处视神经直径与临床活动度评分、平均缺损和模式标准差相关。

诊断标准与关键数值

  • 球后3 mm处ONSS预测DON:AUC=0.957,敏感度=0.907,特异度=0.9。
  • 球后3 mm处视神经水分数诊断DON的特异度=0.967。

临床应用与阅片要点

  • 作者认为视神经水分数和球后3 mm处ONSS是诊断DON有前景且易于获取的影像学标志物。
  • 阅片时可关注球后3 mm和6 mm处视神经直径、水分数及ONSS的定量测量,这些指标与临床活动度评分、平均缺损和模式标准差相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the optic nerve and CSF in the optic nerve sheath as imaging markers of dysthyroid optic neuropathy (DON).

METHODS: In this single-centre retrospective study, orbital images of 30 consecutive participants (54 orbits) with DON, 30 patients (60 orbits) with thyroid-associated ophthalmopathy (TAO) without DON, and 19 healthy controls (HCs; 38 orbits) were analysed. The diameter and cross-sectional area of the optic nerve and its sheath, water fraction of the optic nerve, and volume of the fluid in the optic nerve sheath were measured and compared. The associations between MR parameters and clinical measures were assessed using correlation analysis.

RESULTS: The diameter and water fraction of the optic nerve (3 mm and 6 mm behind the eyeball), optic nerve subarachnoid space (ONSS) (3 mm and 6 mm behind the eyeball), and subarachnoid fluid volume in the optic nerve sheath were significantly greater in the DON group than in the TAO group (p < 0.01) or HC group (p < 0.01). ROC analysis showed that ONSS 3 mm behind the eyeball (ONSS3) was a robust predictor of DON (AUC = 0.957, sensitivity = 0.907, specificity = 0.9). Water fraction of the optic nerve 3 mm behind the eyeball (water fraction3) had the best specificity (0.967). Water fraction3, fluid volume in the optic nerve sheath, and optic nerve diameter (3 mm behind the eyeball) were correlated with clinical measures (i.e. clinical activity score, mean defect, and pattern standard deviation).

CONCLUSIONS: Increased water fraction of the optic nerve and ONSS3 are promising and easily accessible radiological markers for diagnosing DON.

KEY POINTS: • The water fraction of the optic nerve and optic nerve subarachnoid space (ONSS) are greater in patients with dysthyroid optic neuropathy (DON) than in patients with thyroid-associated ophthalmopathy (TAO) without DON. • The optic nerve and the cerebrospinal fluid in the optic nerve sheath measures are associated with visual dysfunction. • The water fraction of the optic nerve and ONSS may be promising imaging markers for diagnosing DON.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wu H, Luo B, Yuan G, et al. The diagnostic value of the IDEAL-T2WI sequence in dysthyroid optic neuropathy: a quantitative analysis of the optic nerve and cerebrospinal fluid in the optic nerve sheath. Eur Radiol. 2021. PMID: 33993334. doi:10.1007/s00330-021-08030-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。