基于合成MRI的T1图信息在动态对比增强成像中的应用:与固定基线T1值方法的比较研究
本研究回顾性纳入102例同时接受DCE和合成脑MRI的患者,比较固定基线T1值与合成MRI T1图两种方法计算的药代动力学参数。结果显示不同脑区两种方法的Ktrans、ve、vp存在显著差异,但T1图法观察者间一致性可比。结论认为合成MRI T1图法能反映个体差异,在DCE MRI临床应用中可能有用。
要点
- 固定基线T1法与合成MRI T1图法在正常额叶白质、枕叶白质及基底节区计算的Ktrans、ve、vp存在显著差异。
- T1图法的观察者间一致性与固定基线T1值法相当。
- 合成MRI T1图法可反映个体T1差异,可能提高DCE MRI参数测量的可靠性。
诊断标准与关键数值
- 在正常表现额叶白质中,固定值法的Ktrans、ve、vp均值显著高于T1图法。
- 在正常表现枕叶白质中,固定值法的ve和vp均值显著高于T1图法。
- 在壳核和尾状核头中,固定值法的Ktrans、ve、vp均值显著低于T1图法。
- T1图法显示与固定基线T1值法相当的观察者间一致性。
临床应用与阅片要点
- 阅片时需注意基线T1值的选择会影响DCE MRI药代动力学参数,不同脑区差异方向可能不同。
- 合成MRI T1图法可提供个体化基线T1,避免固定值法在不同脑区引入的系统偏差。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values.
MATERIALS AND METHODS: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability.
RESULTS: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method.
CONCLUSION: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.
引用
- Shin DJ, Choi SH, Yoo RE, et al. Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method. Korean J Radiol. 2021. PMID: 33987992. doi:10.3348/kjr.2020.1201
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。