文献速递神经儿科影像MR

弥漫性内生性脑桥胶质瘤的影像基因组学:组织学与生物学特征和多模态MRI的相关性

Radiogenomics of diffuse intrinsic pontine gliomas (DIPGs): correlation of histological and biological characteristics with multimodal MRI features.
PubMed 文献 · Eur Radiol · 2021-05-18

本研究前瞻性纳入27例初治、病理确诊的H3K27M突变DIPG患儿,在活检前行多b值DWI、ASL和DSC灌注成像,测量活检部位的ADC、CBF和CBV,并与组织学定量数据及基因表达谱进行相关分析。结果显示H3.1K27M突变肿瘤的ADC值高于H3.3K27M突变肿瘤,而灌注值较低;DSC-rCBV与H3K27M阳性细胞核密度呈正相关。

要点

  • H3.1K27M突变DIPG的ADC值高于H3.3K27M突变者,灌注值则较低。
  • DSC-rCBV与H3K27M阳性细胞核密度呈正相关。
  • ADC值与细胞核密度、灌注值与微血管密度均无直接相关性。

核心结论

  • H3.1K27M突变肿瘤的ADC值高于H3.3K27M突变肿瘤,而灌注值较低,且与微血管密度或细胞核密度无直接相关性。
  • 这种差异可能源于组织水肿,或与门控通道活性相关基因表达有关。

研究设计与样本

  • 前瞻性纳入27例初治、病理确诊的H3K27M突变DIPG患儿。
  • 活检前完成多b值DWI、ASL和DSC灌注成像,并在活检部位测量ADC、CBF和CBV。
  • 评估定量组织学数据(微血管密度、细胞核密度、H3K27M阳性细胞核密度)并进行基因表达谱分析。
  • 按组蛋白亚型分组比较影像与组织病理数据,并将MRI定量数据与组织学及基因表达进行相关分析。

关键影像表现/征象

  • H3.1K27M突变肿瘤ADC值中位数3151 μm²/s,高于H3.3K27M突变肿瘤的1741 μm²/s(p=0.003)。
  • H3.1K27M突变肿瘤DSC-rCBF中位数0.71,低于H3.3K27M突变肿瘤的1.43(p=0.002)。
  • H3.1K27M突变肿瘤DSC-rCBV中位数1.00,低于H3.3K27M突变肿瘤的1.71(p=0.02)。
  • H3.1K27M突变肿瘤H3K27M阳性细胞核密度较低(p=0.007),但微血管密度和细胞核密度与H3.3K27M突变肿瘤相似。
  • 活检样本取自肿瘤强化区者微血管密度高于非强化区(p=0.03),但H3K27M阳性细胞核密度相似(p=0.84)。

诊断标准与关键数值

  • ADC值区分H3.1K27M与H3.3K27M突变肿瘤:中位数3151 μm²/s vs 1741 μm²/s,p=0.003。
  • DSC-rCBF区分H3.1K27M与H3.3K27M突变肿瘤:中位数0.71 vs 1.43,p=0.002。
  • DSC-rCBV区分H3.1K27M与H3.3K27M突变肿瘤:中位数1.00 vs 1.71,p=0.02。
  • DSC-rCBV与H3K27M阳性细胞核密度正相关:rho=0.74,p=0.02。
  • 门控通道活性相关基因表达与ADC值呈负相关趋势,与DSC灌注呈正相关趋势。

临床应用与阅片要点

  • 在DIPG活检前评估多模态MRI,可提示H3.1K27M与H3.3K27M突变亚型:ADC较高且灌注较低者倾向H3.1K27M。
  • ADC值与细胞核密度、灌注值与微血管密度无直接相关性,解读时应结合基因表达及组织水肿等因素。
  • 活检部位应参考强化区,因强化区微血管密度较高,但H3K27M阳性细胞核密度在强化区与非强化区相似。

局限性

  • 样本量较小(27例),仅纳入H3K27M突变DIPG患儿。
  • 研究为单中心前瞻性设计,结果需外部验证。
  • 基因表达与影像的相关性仅为趋势性结果,未报告具体统计值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The diffuse intrinsic pontine gliomas (DIPGs) are now defined by the type of histone H3 mutated at lysine 27. We aimed to correlate the multimodal MRI features of DIPGs, H3K27M mutant, with their histological and molecular characteristics.

METHODS: Twenty-seven treatment-naïve children with histopathologically confirmed DIPG H3K27M mutant were prospectively included. MRI performed prior to biopsy included multi-b-value diffusion-weighted imaging, ASL, and dynamic susceptibility contrast (DSC) perfusion imaging. The ADC and cerebral blood flow (CBF) and blood volume (CBV) were measured at the biopsy site. We assessed quantitative histological data, including microvascular density, nuclear density, and H3K27M-positive nuclear density. Gene expression profiling was also assessed in the samples. We compared imaging and histopathological data according to histone subgroup. We correlated MRI quantitative data with histological data and gene expression.

RESULTS: H3.1K27M mutated tumors showed higher ADC values (median 3151 μm2/s vs 1741 μm2/s, p = 0.003), and lower perfusion values (DSC-rCBF median 0.71 vs 1.43, p = 0.002, and DSC-rCBV median 1.00 vs 1.71, p = 0.02) than H3.3K27M ones. They had similar microvascular and nuclear density, but lower H3K27M-positive nuclear density (p = 0.007). The DSC-rCBV was positively correlated to the H3K27M-positive nuclear density (rho = 0.74, p = 0.02). ADC values were not correlated with nuclear density nor perfusion values with microvascular density. The expression of gated channel activity-related genes tended to be inversely correlated with ADC values and positively correlated with DSC perfusion.

CONCLUSIONS: H3.1K27M mutated tumors have higher ADC and lower perfusion values than H3.3K27M ones, without direct correlation with microvascular or nuclear density. This may be due to tissular edema possibly related to gated channel activity-related gene expression.

KEY POINTS: • H3.1K27M mutant DIPG had higher apparent diffusion coefficient (p = 0.003), lower α (p = 0.048), and lower relative cerebral blood volume (p = 0.02) than H3.3K27M mutant DIPG at their biopsy sites. • Biopsy samples obtained within the tumor's enhancing portion showed higher microvascular density (p = 0.03) than samples obtained outside the tumor's enhancing portion, but similar H3K27M-positive nuclear density (p = 0.84). • Relative cerebral blood volume measured at the biopsy site was significantly correlated with H3K27M-positive nuclear density (rho = 0.74, p = 0.02).

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Calmon R, Dangouloff-Ros V, Varlet P, et al. Radiogenomics of diffuse intrinsic pontine gliomas (DIPGs): correlation of histological and biological characteristics with multimodal MRI features. Eur Radiol. 2021. PMID: 34003354. doi:10.1007/s00330-021-07991-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。