文献速递神经外周血管MRPET

Hadamard编码ASL MRI筛查成人缺血性烟雾病CBF降低的诊断准确性

Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-05-20

Hadamard编码多延迟ASL MRI可检测成人缺血性烟雾病患者的CBF降低,敏感度和阴性预测值均为100%,有望作为筛查工具。

要点

  • Hadamard编码多延迟ASL检测CBF降低的敏感度和阴性预测值均为100%。
  • 以SPECT-CBF比值<0.686为参考标准,适合用于成人缺血性烟雾病筛查。

核心结论

  • Hadamard编码多延迟ASL MRI可检测成人缺血性烟雾病患者的CBF降低,敏感度和阴性预测值均为100%,有望作为筛查工具。

研究设计与样本

  • Hadamard编码多延迟基于7个子脉冲(不同标记时长和延迟组合)逐体素计算经动脉通过时间校正的CBF。
  • 使用3D立体定向模板自动在症状侧大脑半球同侧小脑半球和5个MCA供血区放置ROI,计算MCA/小脑ROI比值。

诊断标准与关键数值

  • Hadamard编码多延迟ASL的敏感度为100%(95%CI 100%-100%),阴性预测值显著高于标准延迟ASL(敏感度95%CI 44%-80%,阴性预测值95%CI 88%-97%)。

临床应用与阅片要点

  • Hadamard编码多延迟ASL可无创筛查成人缺血性烟雾病的CBF降低,高阴性预测值有助于排除低灌注。
  • 阅片时建议计算MCA/小脑ROI比值,并与SPECT-CBF比值<0.686的参考阈值对照。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Adult patients with ischemic Moyamoya disease are advised to undergo selective revascularization surgery based on cerebral hemodynamics. The purpose of this study was to determine the diagnostic accuracy of arterial spin-labeling MR imaging using Hadamard-encoded multiple postlabeling delays for the detection of reduced CBF in such patients.

MATERIALS AND METHODS: Thirty-seven patients underwent brain perfusion SPECT and pseudocontinuous arterial spin-labeling MR imaging using standard postlabeling delay (1525 ms) and Hadamard-encoded multiple postlabeling delays. For Hadamard-encoded multiple postlabeling delays, based on data obtained from the 7 sub-boluses with combinations of different labeling durations and postlabeling delays, CBF corrected by the arterial transit time was calculated on a voxel-by-voxel basis. Using a 3D stereotaxic template, we automatically placed ROIs in the ipsilateral cerebellar hemisphere and 5 MCA territories in the symptomatic cerebral hemisphere; then, the ratio of the MCA to cerebellar ROI was calculated.

RESULTS: The area under the receiver operating characteristic curve for detecting reduced SPECT-CBF ratios (<0.686) was significantly greater for the Hadamard-encoded multiple postlabeling delays-CBF ratios (0.885) than for the standard postlabeling delay-CBF ratios (0.786) (P = .001). The sensitivity and negative predictive value for the Hadamard-encoded multiple postlabeling delays-CBF ratios were 100% (95% confidence interval, 100%-100%) and significantly higher than the sensitivity (95% CI, 44%-80%) and negative predictive value (95% CI, 88%-97%) for the standard postlabeling delay-CBF ratio, respectively.

CONCLUSIONS: ASL MR imaging using Hadamard-encoded multiple postlabeling delays may be applicable as a screening tool because it can detect reduced CBF on brain perfusion SPECT with 100% sensitivity and a 100% negative predictive value in adult patients with ischemic Moyamoya disease.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Setta K, Matsuda T, Sasaki M, et al. Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease. AJNR Am J Neuroradiol. 2021. PMID: 34016589. doi:10.3174/ajnr.A7167

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。