文献速递神经头颈MRCT

MR弹性成像测量的剪切硬度与灌注CT测量的脑膜瘤灌注指标之间的关系

Relationship between Shear Stiffness Measured by MR Elastography and Perfusion Metrics Measured by Perfusion CT of Meningiomas.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-05-13

本研究探讨了脑膜瘤MR弹性成像测量的硬度与灌注CT测量的灌注指标之间的相关性,并评估二者预测术中肿瘤质地及鉴别组织学亚型的能力。

要点

  • MR弹性成像测量的肿瘤硬度有助于预测脑膜瘤术中质地。
  • 相对MTT与肿瘤硬度呈负相关,或可间接反映硬度。
  • 相对MTT有助于鉴别过渡型与脑膜上皮型脑膜瘤。

局限性

  • 样本量小(队列1仅14例,队列2共18例)。
  • 单中心研究。
  • 术中质地分级由神经外科医生主观评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: When managing meningiomas, intraoperative tumor consistency and histologic subtype are indispensable factors influencing operative strategy. The purposes of this study were the following: 1) to investigate the correlation between stiffness assessed with MR elastography and perfusion metrics from perfusion CT, 2) to evaluate whether MR elastography and perfusion CT could predict intraoperative tumor consistency, and 3) to explore the predictive value of stiffness and perfusion metrics in distinguishing among histologic subtypes of meningioma.

MATERIALS AND METHODS: Mean tumor stiffness and relative perfusion metrics (blood flow, blood volume, and MTT) were calculated (relative to normal brain tissue) for 14 patients with meningiomas who underwent MR elastography and perfusion CT before surgery (cohort 1). Intraoperative tumor consistency was graded by a neurosurgeon in 18 patients (cohort 2, comprising the 14 patients from cohort 1 plus 4 additional patients). The correlation between tumor stiffness and perfusion metrics was evaluated in cohort 1, as was the ability of perfusion metrics to predict intraoperative tumor consistency and discriminate histologic subtypes. Cohort 2 was analyzed for the ability of stiffness to determine intraoperative tumor consistency and histologic subtypes.

RESULTS: The relative MTT was inversely correlated with stiffness (P = .006). Tumor stiffness was positively correlated with intraoperative tumor consistency (P = .01), while perfusion metrics were not. Relative MTT significantly discriminated transitional meningioma from meningothelial meningioma (P = .04), while stiffness did not significantly differentiate any histologic subtypes.

CONCLUSIONS: In meningioma, tumor stiffness may be useful to predict intraoperative tumor consistency, while relative MTT may potentially correlate with tumor stiffness and differentiate transitional meningioma from meningothelial meningioma.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Takamura T, Motosugi U, Ogiwara M, et al. Relationship between Shear Stiffness Measured by MR Elastography and Perfusion Metrics Measured by Perfusion CT of Meningiomas. AJNR Am J Neuroradiol. 2021. PMID: 33985944. doi:10.3174/ajnr.A7117

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。