CT灌注成像评估脑硬膜动脉血管融通术治疗烟雾病综合征的疗效
结果发现,无论DSA显示侧支血管形成丰富还是不良,手术区脑组织灌注均有改善;rTTP显著改善可能提示丰富侧支血管形成。临床改善与CTP改善一致性较好,而与DSA侧支血管形成程度一致性较差。
要点
- EDAS术后手术区脑灌注改善不依赖于DSA侧支血管形成程度。
- rTTP显著改善可能提示丰富侧支血管形成。
- CTP可定量评估EDAS术后脑组织灌注改善。
关键影像表现/征象
- CTP测量同侧皮层、对侧镜像区及脑桥区域的rCBF、rCBV、rMTT和rTTP。
- 术后DSA侧支血管形成丰富组(2、3级)和不良组(0、1级)的rCBF和rMTT均显著改善。
- rTTP仅在侧支血管形成丰富组显著改善。
诊断标准与关键数值
- 根据术后DSA侧支血管形成程度分为丰富组(2、3级)和不良组(0、1级)。
- 术后CTP在丰富组和1级侧支血管组中改善(p < 0.01)。
- 临床改善与CTP改善一致性较好(p = 0.07),与DSA侧支血管形成程度一致性较差(p = 0.003)。
临床应用与阅片要点
- CTP可用于EDAS术后随访评估脑组织灌注改善。
- rTTP显著改善可能提示侧支血管形成丰富。
- 临床改善与CTP改善一致性较好,而与DSA侧支分级一致性较差。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To explore the value of computed tomography perfusion (CTP) imaging for evaluating the efficacy of encephaloduroarteriosynangiosis (EDAS) treatment of moyamoya syndrome (MMS).
METHODS: Forty-three patients with MMS (48 hemispheres) who received EDAS treatment were examined using CTP and DSA before and after surgery. CTP of the ipsilateral cortex, contralateral mirror area, and pons region were measured, and the relative cerebral blood flow (rCBF) and volume (rCBV), mean transit time (rMTT), and time-to-peak (rTTP) were calculated. Based on postoperative DSA, 48 hemispheres were apportioned to two groups based on rich (grades 2, 3) or poor (grades 0, 1) collateral vessel formation, and the pre- and post-operative differences in perfusion changes were compared. The association between clinical outcome, CTP, and the degree of DSA collateral vessels was explored.
RESULTS: rCBF and rMTT significantly improved in both the poor and rich collateral vessel formation groups (n = 21 and 27, respectively), while rTTP significantly improved only in the latter. Postoperative CTP improved in the rich and the grade 1 collateral vessel groups (p < 0.01). The clinical improvement was consistent with the improvement of CTP (p = 0.07), but less consistent with the degree of collateral angiogenesis (p = 0.003).
CONCLUSION: CTP can quantitatively evaluate the improvement of brain tissue perfusion in the operated area after EDAS. Brain tissue perfusion in operated areas improved regardless of postoperative rich or poor collateral vessel formation observed via DSA. A significant improvement in rTTP in the operated area may indicate the formation of abundant collateral vessels.
KEY POINTS: • CTP showed that brain tissue perfusion in the operated area after EDAS improved regardless of rich or poor collateral vessel formation observed via DSA. • Significant improvement of rTTP in the operated area may indicate the formation of abundant collateral vessels.
引用
- Guo X, Yuan X, Gao L, et al. Encephaloduroarteriosynangiosis (EDAS) treatment of moyamoya syndrome: evaluation by computed tomography perfusion imaging. Eur Radiol. 2021. PMID: 33956177. doi:10.1007/s00330-021-07960-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。