瘤周静息态BOLD fMRI不同步性预测脑膜瘤分级与侵袭

Asynchrony in Peritumoral Resting-State Blood Oxygen Level-Dependent fMRI Predicts Meningioma Grade and Invasion.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-05-13

本研究纳入25例I级和11例II/III级脑膜瘤患者,从肿瘤及影像学正常对照半球提取BOLD时间序列,构建不同步性图并计算超出强化肿瘤的掩模比例。结果显示BOLD不同步空间范围在高分级肿瘤中更大(P<0.001),可高精度区分分级(AUC=0.88)。

要点

  • 瘤周BOLD不同步性范围越大,脑膜瘤分级越高。
  • BOLD不同步性图可辅助无创区分I级与II/III级脑膜瘤。
  • 不同步区域可能为活检提供靶点以改善组织学诊断。

关键影像表现/征象

  • 不同步性图中负值表示与健康脑同步,正值表示异步活动。
  • 高分级(II/III级)肿瘤的BOLD不同步空间范围大于低分级(I级)肿瘤。
  • 计算不同步掩模超出对比增强肿瘤的比例以量化瘤周不同步范围。

诊断标准与关键数值

  • BOLD不同步空间范围区分高分级与低分级肿瘤的P<0.001。
  • BOLD不同步性区分脑膜瘤分级的AUC=0.88。

临床应用与阅片要点

  • 阅片时可关注瘤周BOLD不同步范围,范围较大提示高分级可能。
  • 对怀疑高分级但组织取样不足者,不同步区域可考虑作为活检靶点。
  • 需注意不同步信号为功能标记,应结合常规影像与组织学综合判断。

局限性

  • 单中心研究设计可能限制外推性。
  • 未报告设备场强、序列参数及不同步性阈值等具体细节。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Meningioma grade is determined by histologic analysis, with detectable brain invasion resulting in a diagnosis of grade II or III tumor. However, tissue undersampling is a common problem, and invasive parts of the tumor can be missed, resulting in the incorrect assignment of a lower grade. Radiographic biomarkers may be able to improve the diagnosis of grade and identify targets for biopsy. Prior work in patients with gliomas has shown that the resting-state blood oxygen level-dependent fMRI signal within these tumors is not synchronous with normal brain. We hypothesized that blood oxygen level-dependent asynchrony, a functional marker of vascular dysregulation, could predict meningioma grade.

MATERIALS AND METHODS: We identified 25 patients with grade I and 11 patients with grade II or III meningiomas. Blood oxygen level-dependent time-series were extracted from the tumor and the radiographically normal control hemisphere and were included as predictors in a multiple linear regression to generate a blood oxygen level-dependent asynchrony map, in which negative values signify synchronous and positive values signify asynchronous activity relative to healthy brain. Masks of blood oxygen level-dependent asynchrony were created for each patient, and the fraction of the mask that extended beyond the contrast-enhancing tumor was computed.

RESULTS: The spatial extent of blood oxygen level-dependent asynchrony was greater in high (grades II and III) than in low (I) grade tumors (P < 0.001) and could discriminate grade with high accuracy (area under the curve = 0.88).

CONCLUSIONS: Blood oxygen level-dependent asynchrony radiographically discriminates meningioma grade and may provide targets for biopsy collection to aid in histologic diagnosis.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Wu PB, Chow DS, Petridis PD, et al. Asynchrony in Peritumoral Resting-State Blood Oxygen Level-Dependent fMRI Predicts Meningioma Grade and Invasion. AJNR Am J Neuroradiol. 2021. PMID: 33985949. doi:10.3174/ajnr.A7154

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。