如何停用钆螯合物进行磁共振成像:ferumoxytol的临床转化经验
本文综述了ferumoxytol作为替代钆螯合物的MRI对比剂在儿童中的应用。钆沉积于脑内数月或数年令人担忧,尤其对发育中的儿童脑更易受外源性毒素影响。FDA批准的铁补充剂ferumoxytol由氧化铁纳米颗粒组成,可在MRI上检测并显著增强血管和软组织的T1和T2信号。多个研究组包括作者团队已超说明书使用ferumoxytol作为新型MRI对比剂。本文回顾了现有文献关于ferumoxytol在儿童体内的生物分布,并比较了ferumoxytol与钆螯合物增强MRI的诊断准确性。氧化铁纳米颗粒代表了一类有前景的新型儿童MRI对比剂,可被代谢且不沉积于脑内。
要点
- ferumoxytol可提供显著的T1和T2信号增强,用于血管和软组织成像。
- ferumoxytol可被代谢且不沉积于脑内,适合儿童MRI替代钆螯合物。
- 需比较ferumoxytol与钆螯合物增强MRI的诊断准确性。
关键影像表现/征象
- ferumoxytol由氧化铁纳米颗粒组成,可在MRI上检测并显著增强血管和软组织的T1和T2信号。
临床应用与阅片要点
- 在儿童MRI中可考虑使用ferumoxytol替代钆螯合物,以避免钆在脑内沉积。
- 需注意ferumoxytol为超说明书使用,应关注其生物分布和诊断准确性。
局限性
- 本文为综述,未报告原始研究的具体样本量、中心数及诊断准确性数值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Gadolinium chelates have been used as standard contrast agents for clinical MRI for several decades. However, several investigators recently reported that rare Earth metals such as gadolinium are deposited in the brain for months or years. This is particularly concerning for children, whose developing brain is more vulnerable to exogenous toxins compared to adults. Therefore, a search is under way for alternative MR imaging biomarkers. The United States Food and Drug Administration (FDA)-approved iron supplement ferumoxytol can solve this unmet clinical need: ferumoxytol consists of iron oxide nanoparticles that can be detected with MRI and provide significant T1- and T2-signal enhancement of vessels and soft tissues. Several investigators including our research group have started to use ferumoxytol off-label as a new contrast agent for MRI. This article reviews the existing literature on the biodistribution of ferumoxytol in children and compares the diagnostic accuracy of ferumoxytol- and gadolinium-chelate-enhanced MRI. Iron oxide nanoparticles represent a promising new class of contrast agents for pediatric MRI that can be metabolized and are not deposited in the brain.
引用
- Daldrup-Link HE, Theruvath AJ, Rashidi A, et al. How to stop using gadolinium chelates for magnetic resonance imaging: clinical-translational experiences with ferumoxytol. Pediatr Radiol. 2021. PMID: 34046709. doi:10.1007/s00247-021-05098-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。