文献速递神经技术与安全MR

合成MRI脑容积与分形分析:与传统3D T1加权成像的对比研究

Brain volumetric and fractal analysis of synthetic MRI: A comparative study with conventional 3D T1-weighted images.
PubMed 文献 · Eur J Radiol · 2021-05-21

结果显示平面内和层间分辨率均影响脑容积测量,但脑实质体积在合成MRI不同采集间一致性高,且与3D T1WI关联强;1×1×4 mm合成MRI在容积和分形分析中与3D T1WI关联最强;灰白质分形维数在两种方法间存在显著差异。

要点

  • 合成MRI脑实质体积测量在不同分辨率间一致性高,与3D T1WI关联强。
  • 1×1×4 mm合成MRI的容积和分形测量最接近3D T1WI。
  • 灰质和白质分形维数在合成MRI与3D T1WI间存在显著差异。

核心结论

  • 合成MRI脑容积和分形测量受空间分辨率影响,较高平面内和较低层间分辨率(1×1×4 mm)最接近3D T1WI。

研究设计与样本

  • 采用Kruskal-Wallis检验和Dwass-Steel-Critchlow-Fligner事后检验评估合成MRI测量的一致性,线性回归模型评估合成MRI与3D T1WI测量的关联。

诊断标准与关键数值

  • 合成MRI与3D T1WI的容积和分形测量关联用线性回归模型评估,未报告具体敏感度、特异度、AUC或阈值。

临床应用与阅片要点

  • 日常使用合成MRI进行脑容积测量时,选择1×1×4 mm分辨率可能使结果更接近3D T1WI。
  • 注意合成MRI与3D T1WI在灰白质分形维数上存在显著差异,报告分形分析结果时需谨慎。

局限性

  • 为单中心研究,结果外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The estimation of brain volumetric measurements based on Synthetic MRI (SyMRI) is easy and fast, however, the consistency of brain volumetric and morphologic measurements based on SyMRI and 3D T1WI should be further addressed. The current study evaluated the impact of spatial resolution on brain volumetric and morphologic measurements using SyMRI, and test whether the brain measurements derived from SyMRI were consistent with those resulted from 3D T1WI.

METHOD: Brain volumetric and fractal analysis were applied to thirty healthy subjects, each underwent four SyMRI acquisitions with different spatial resolutions (1 × 1 × 2 mm, 1 × 1x3mm, 1 × 1 × 4 mm, 2 × 2 × 2 mm) and a 3D T1WI (1 × 1 × 1 mm isotropic). The consistency of the SyMRI measurements was tested using one-way non-parametric Kruskal-Wallis test and post hoc Dwass-Steel-Critchlow-Fligner test. The association between SyMRI and 3D T1WI derived measurements was evaluated using linear regression models.

RESULTS: Our results demonstrated that both in- and through-plane resolutions show an impact on brain volumetric measurements, while brain parenchymal volume showed high consistency across the SyMRI acquisitions, and high association with the measurements from 3D T1WI. In addition, SyMRI with 1 × 1 × 4 mm resolution showed the strongest association with 3D T1WI compared to other SyMRI acquisitions in both volumetric and fractal analyses. Moreover, substantial differences were found in fractal dimension of both gray and white matter between the SyMRI and 3D T1WI tissue segmentations.

CONCLUSIONS: Our results suggested that the measurements from SyMRI with relatively higher in-plane and lower through-plane resolution (1 × 1 × 4 mm) are much closer to 3D T1WI.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu S, Meng T, Russo C, et al. Brain volumetric and fractal analysis of synthetic MRI: A comparative study with conventional 3D T1-weighted images. Eur J Radiol. 2021. PMID: 34049059. doi:10.1016/j.ejrad.2021.109782

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。