文献速递神经技术与安全MR

同时多层采集加速临床神经放射学方案中的扩散MRI

Simultaneous Multislice for Accelerating Diffusion MRI in Clinical Neuroradiology Protocols.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-05-13

本研究回顾性比较了临床扩散序列在实施2层同时多层加速及改变扩散梯度采样方案前后的表现,由2名神经放射学家独立盲法评估图像质量、伪影和整体诊断效用。结果显示加速后常规扩散采集时间从141秒降至45秒,扩散纤维束成像从7.5分钟降至5.9分钟,诊断效用被评为等效,纤维束成像临床等效,皮质脊髓束和弓状束的Dice相似系数分别为0.78和0.71。

要点

  • 2层同时多层加速可将常规扩散采集从141秒缩短至45秒,纤维束成像从7.5分钟缩短至5.9分钟。
  • 加速序列主观图像质量下降,但诊断效用和纤维束成像临床等效。
  • 纤维束体积空间重叠Dice系数:皮质脊髓束0.78,弓状束0.71。

关键影像表现/征象

  • 同时多层加速扩散序列的主观图像质量评分降低,但诊断效用被评为等效。
  • 同时多层加速扩散纤维束成像被评估为临床等效。
  • 常规与同时多层生成的皮质脊髓束和弓状束纤维束体积Dice相似系数分别为0.78(SD,0.03)和0.71(SD,0.05)。

诊断标准与关键数值

  • 常规扩散采集时间从141秒降至45秒,扩散纤维束成像从7.5分钟降至5.9分钟。
  • 扩散纤维束成像参数:b=0,1000,2000 s/mm2;60方向。
  • 皮质脊髓束Dice相似系数0.78(SD,0.03),弓状束0.71(SD,0.05)。

临床应用与阅片要点

  • 在临床神经放射学方案中可采用2层同时多层加速扩散序列以显著缩短采集时间。
  • 需注意加速后主观图像质量下降,但诊断效用和纤维束成像临床等效。
  • 纤维束成像空间重叠度中等(Dice 0.71–0.78),报告时应结合原始图像综合判断。

局限性

  • 回顾性研究设计。
  • 每组样本量较小(n=25),纤维束成像仅13例。
  • 单中心、单扫描仪(3T)和单线圈(20通道)设置。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Diffusion MR imaging sequences essential for clinical neuroradiology imaging protocols may be accelerated with simultaneous multislice acquisitions. We tested whether simultaneous multislice-accelerated diffusion data were clinically equivalent to standard acquisitions.

MATERIALS AND METHODS: In this retrospective study, clinical diffusion sequences obtained before and after implementation of 2-slice simultaneous multislice acceleration and an altered diffusion gradient sampling scheme using the same 3T MRI scanner and 20-channel coil (n = 25 per group) were independently and blindly evaluated by 2 neuroradiologists for perceived quality, artifacts, and overall diagnostic utility. Diffusion tractography was performed in 13 patients both with and without 2-slice simultaneous multislice acceleration (b = 0, 1000, 2000 s/mm2; 60 directions). The corticospinal tract and arcuate fasciculus ipsilateral to the lesion were generated using the same ROIs and then blindly assessed by a neurosurgeon for anatomic fidelity, perceived quality, and impact on surgical management. Tract volumes were compared for spatial overlap.

RESULTS: Two-slice simultaneous multislice diffusion reduced acquisition times from 141 to 45 seconds for routine diffusion and from 7.5 to 5.9 minutes for diffusion tractography using 3T MR imaging. The simultaneous multislice-accelerated diffusion sequence was rated equivalent for diagnostic utility despite reductions to perceived image quality. Simultaneous multislice-accelerated diffusion tractography was rated clinically equivalent. Dice similarity coefficients between routine and simultaneous multislice-generated corticospinal tract and arcuate fasciculus tract volumes were 0.78 (SD, 0.03) and 0.71 (SD, 0.05), respectively.

CONCLUSIONS: Two-slice simultaneous multislice diffusion appeared clinically equivalent for standard acquisitions and diffusion tractography. Simultaneous multislice makes it feasible to acquire higher angular and q-space-resolution diffusion acquisitions required for translating advanced diffusion models into clinical practice.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Hoch MJ, Bruno M, Pacione D, et al. Simultaneous Multislice for Accelerating Diffusion MRI in Clinical Neuroradiology Protocols. AJNR Am J Neuroradiol. 2021. PMID: 33985946. doi:10.3174/ajnr.A7140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。