剪切波弹性成像可识别不稳定颈动脉斑块
研究纳入97例颈动脉狭窄≥50%患者,用剪切波弹性成像测量斑块弹性,比较无症状稳定、无症状进展和有症状斑块。无症状稳定斑块平均弹性52.2 kPa,显著高于无症状进展组30.4 kPa(p<0.001)和有症状组36.4 kPa(p=0.033);后两组间无显著差异(p>0.1)。常规超声特征各组无差异。
要点
- 无症状稳定斑块平均弹性52.2 kPa,高于无症状进展斑块30.4 kPa(p<0.001)。
- 无症状稳定斑块平均弹性52.2 kPa,高于有症状斑块36.4 kPa(p=0.033)。
- 无症状进展斑块与有症状斑块平均弹性无显著差异(p>0.1)。
核心结论
- 剪切波弹性成像有助于区分颈动脉稳定与不稳定动脉粥样硬化斑块。
研究设计与样本
- 连续纳入颈动脉分叉斑块研究中的患者,共97例:无症状稳定狭窄74例、无症状进展狭窄12例、有症状狭窄11例;采用B型超声和剪切波弹性成像测量斑块平均、最大和最小弹性。
关键影像表现/征象
- 无症状稳定、无症状进展和有症状斑块在回声性、钙化、均匀性、溃疡表面及斑块内出血方面均无差异(所有p>0.05)。
诊断标准与关键数值
- 无症状稳定斑块组平均弹性52.2 kPa,无症状进展斑块组30.4 kPa(p<0.001)。
- 无症状稳定斑块组平均弹性52.2 kPa,有症状斑块组36.4 kPa(p=0.033)。
- 无症状进展斑块组与有症状斑块组平均弹性无显著差异(p>0.1)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Shear-wave elastography (SWE) is a novel ultrasound technique for quantifying tissue elasticity. The aim of this study was to identify differences in atherosclerotic plaque elasticity measured using SWE among individuals with symptomatic, asymptomatic progressive and asymptomatic stable carotid plaques. Consecutive patients from the Atherosclerotic Plaque Characteristics Associated with a Progression Rate of the Plaque and a Risk of Stroke in Patients with the Carotid Bifurcation Plaque Study were screened for this research. Neurosonography examination of carotid arteries was performed to identify plaque stenosis of ≥50% using B-mode ultrasound and SWE imaging to measure the mean, maximal and minimal elasticity. The set consisted of 97 participants-74 with asymptomatic stable stenosis, 12 with asymptomatic progressive stenosis and 11 with symptomatic stenosis. The mean elasticity in the asymptomatic stable plaque group was significantly higher than in the asymptomatic progressive (52.2 vs. 30.4 kPa; p < 0.001) and symptomatic (52.2 vs. 36.4 kPa; p = 0.033) plaque groups. No significant differences were found between asymptomatic progressive and symptomatic (p > 0.1) plaque groups. Asymptomatic stable, asymptomatic progressive and symptomatic plaques did not differ in echogenicity, calcifications, homogeneity, occurrence of ulcerated surface, or intra-plaque hemorrhage (p > 0.05 in all cases). SWE was a helpful modality for differentiating between stable and unstable atherosclerotic plaques in carotid arteries.
引用
- Školoudík D, Kešnerová P, Vomáčka J, et al. Shear-Wave Elastography Enables Identification of Unstable Carotid Plaque. Ultrasound Med Biol. 2021. PMID: 33931284. doi:10.1016/j.ultrasmedbio.2021.03.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。