文献速递神经儿科影像PET

脑代谢特征区分典型与非典型伴中央颞区棘波的良性癫痫

Brain metabolic characteristics distinguishing typical and atypical benign epilepsy with centro-temporal spikes.
PubMed 文献 · Eur Radiol · 2021-05-29

回顾性纳入46例典型BECTS、31例非典型BECTS和23例对照,用[18F]FDG PET评估代谢不对称指数,发现非典型BECTS的|AI|更高且低代谢范围更广,基于PET的模型AUC高于临床模型(0.91 vs. 0.70,p=0.006),混合模型敏感度0.90、特异度0.85、准确率0.87。

要点

  • 非典型BECTS较典型BECTS显示更广泛、更严重的低代谢,主要位于额-颞-顶叶皮层。
  • PET模型区分典型与非典型BECTS的AUC为0.91,显著高于临床模型的0.70(p=0.006)。
  • 混合模型(代谢+临床变量)分类性能最佳:敏感度0.90、特异度0.85、准确率0.87。

核心结论

  • 非典型BECTS较典型BECTS显示更广泛、更严重的低代谢,基于此可很好地区分两组;代谢特征与临床变量结合有潜力用于临床区分典型与非典型BECTS。

研究设计与样本

  • 回顾性纳入46例典型BECTS、31例非典型BECTS和23例对照,均行[18F]FDG PET检查,采用统计参数图(SPM)分析代谢差异,并以逻辑回归构建临床、PET及混合模型。

关键影像表现/征象

  • 非典型BECTS较典型BECTS显示更多低代谢区域,主要位于额-颞-顶叶皮层。

诊断标准与关键数值

  • 绝对不对称指数(|AI|)用于评估代谢异常严重程度,非典型BECTS的|AI|显著高于典型BECTS(p=0.040);PET模型AUC 0.91 vs. 临床模型0.70(p=0.006);混合模型敏感度0.90、特异度0.85、准确率0.87。

临床应用与阅片要点

  • 作者认为代谢特征与临床变量结合有潜力用于临床区分典型与非典型BECTS;区分两者对制定治疗方案非常重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Atypical benign epilepsy with centro-temporal spikes (BECTS) have less favorable outcomes than typical BECTS, and thus should be accurately identified for adequate treatment. We aimed to investigate the glucose metabolic differences between typical and atypical BECTS using 18F-fluorodeoxyglucose positron emission tomography ([18F]FDG PET) imaging, and explore whether these differences can help distinguish.

METHODS: Forty-six patients with typical BECTS, 31 patients with atypical BECTS and 23 controls who underwent [18F]FDG PET examination were retrospectively involved. Absolute asymmetry index (|AI|) was applied to evaluate the severity of metabolic abnormality. Glucose metabolic differences were investigated among typical BECTS, atypical BECTS, and controls by using statistical parametric mapping (SPM). Logistic regression analyses were performed based on clinical, PET, and hybrid features.

RESULTS: The |AI| was found significantly higher in atypical BECTS than in typical BECTS (p = 0.040). Atypical BECTS showed more hypo-metabolism regions than typical BECTS, mainly located in the fronto-temporo-parietal cortex. The PET model had significantly higher area under the curve (AUC) than the clinical model (0.91 vs. 0.70, p = 0.006). The hybrid model had the highest sensitivity (0.90), specificity (0.85), and accuracy (0.87) of all three models.

CONCLUSIONS: Atypical BECTS showed more widespread and severe hypo-metabolism than typical BECTS, depending on which the two groups can be well distinguished. The combination of metabolic characteristics and clinical variables has the potential to be used clinically to distinguish between typical and atypical BECTS.

KEY POINTS: • Distinguishing between typical and atypical BECTS is very important for the formulation of treatment regimens in clinical practice. • Atypical BECTS showed more widespread and severe hypo-metabolism than typical BECTS, mainly located in the fronto-temporo-parietal cortex. • The logistic regression model based on PET outperformed that based on clinical characteristics in classification of typical and atypical BECTS, and the hybrid model achieved the best classification performance.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li Y, Feng J, Zhang T, et al. Brain metabolic characteristics distinguishing typical and atypical benign epilepsy with centro-temporal spikes. Eur Radiol. 2021. PMID: 34050803. doi:10.1007/s00330-021-08051-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。