文献速递神经介入DSA

WEB装置治疗破裂颅内动脉瘤:国际多中心经验与更新荟萃分析

The Woven EndoBridge device for ruptured intracranial aneurysms: international multicenter experience and updated meta-analysis.
PubMed 文献 · Neuroradiology · 2021-05-25

本研究通过7个三级中心2016-2020年回顾性分析及2011-2020年系统综述与荟萃分析,评估WEB装置治疗动脉瘤性蛛网膜下腔出血(aSAH)的安全性与有效性。结果显示再出血率低,但完全闭塞率低于未破裂动脉瘤,并发症率较高。

要点

  • WEB治疗aSAH再出血率低,但3-6个月完全闭塞率仅61%。
  • WEB治疗aSAH的并发症率和再治疗率高于未破裂动脉瘤。
  • WEB可用于无需抗血小板治疗的宽颈动脉瘤,尤其适合aSAH。

诊断标准与关键数值

  • 多中心队列:再出血0例,再治疗2例,并发症2例,3个月完全闭塞16例,9-12个月完全闭塞21例。
  • 荟萃分析:再出血率2.5%(95%CI 1-5%),再治疗率9%(95%CI 4-17%),并发症率17%(95%CI 10-30%),3-6个月完全闭塞率61%(95%CI 51-71%)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The Woven EndoBridge (WEB) can be used to treat wide-necked aneurysms without antiplatelet medications, suggesting it may have advantages in the setting of aneurysmal subarachnoid hemorrhage (aSAH). The goal was assessment of safety and efficacy of WEB in aSAH given the delayed nature of aneurysmal thrombosis.

METHODS: An international retrospective analysis of patients with aSAH treated with WEB was conducted at 7 tertiary centers from 2016 to 2020. Outcomes included rates of rebleeding, retreatment, complications, and complete occlusion. Furthermore, a systematic review and meta-analysis was conducted from 2011 to 2020 assessing the same outcomes. All pooled event rates were calculated using a random effect model.

RESULTS: Consecutive patients with aSAH harbored 25 aneurysms that were treated with 29 WEB devices. The mean age was 53 years, and 65% were female. Zero experienced rebleeding, 2 were retreated, 2 experienced complications, 16 were completely occluded at 3 months, and 21 were completed occluded at 9-12 months. Meta-analysis of 309 WEB treatments for aSAH from 7 case series revealed 2.5% (95% CI 1-5%) had rebleeding, 9% (95% CI 4-17%) were retreated, 17% (95% CI 10-30%) had complications, and 61% (95% CI 51-71%) were completely occluded at 3-6 months.

CONCLUSION: WEB embolization in the setting of aSAH provides similar protection against rebleeding with comparable retreatment rates to traditional approaches. However, there is a higher rate of incomplete radiographic occlusion and operative complications compared to WEB embolization of unruptured aneurysms. Long-term prospective studies are needed to fully delineate the role of WEB embolization in aSAH.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Harker P, Regenhardt RW, Alotaibi NM, et al. The Woven EndoBridge device for ruptured intracranial aneurysms: international multicenter experience and updated meta-analysis. Neuroradiology. 2021. PMID: 34031704. doi:10.1007/s00234-021-02727-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。