文献速递技术与安全CT

深度学习CT重建临床协议优化的考量

Protocol Optimization Considerations for Implementing Deep Learning CT Reconstruction.
PubMed 文献 · AJR Am J Roentgenol · 2021-04-14

本研究在体模模型上表征了一种深度学习图像重建(DLIR)方法,并与同一厂商的ASIR-V和FBP比较。评估指标包括对比噪声比、空间分辨率、噪声纹理、噪声随层厚的变化及CT值一致性。结果显示DLIR在保持FBP样噪声纹理的同时,不降低空间分辨率,且随层厚减小噪声惩罚更小,有利于临床协议优化。

要点

  • DLIR在体模中保持FBP样噪声纹理,避免ASIR-V的低频噪声偏移。
  • DLIR无空间分辨率下降,且对比噪声比优于FBP。
  • DLIR在薄层时噪声惩罚小于FBP,支持薄层协议优化。

关键影像表现/征象

  • DLIR和ASIR-V在所有剂量和层厚下对比噪声比均优于FBP。
  • DLIR保持类似FBP的噪声纹理,而ASIR-V将噪声功率谱移向低频。
  • DLIR和ASIR-V的空间分辨率未观察到剂量或对比度依赖性。
  • DLIR的噪声随层厚变化与FBP不同,层厚减小时噪声惩罚更小。
  • 所有测量条件下CT值无临床显著变化。

临床应用与阅片要点

  • 临床协议优化时可考虑用DLIR替代FBP或ASIR-V,以在相同剂量下改善图像质量。
  • 利用DLIR薄层噪声惩罚小的特点,可优化薄层扫描协议而不必担心噪声明显增加。
  • DLIR的噪声纹理接近FBP,有助于保持熟悉的图像观感,减少阅片适应成本。

局限性

  • 研究为体模研究,未在患者图像上验证临床诊断性能。
  • 仅评估单一厂商的DLIR和ASIR-V,结果不能直接推广到其他厂商。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. Previous advances over filtered back projection (FBP) have incorporated model-based iterative reconstruction. The purpose of this study was to characterize the latest advance in image reconstruction, that is, deep learning. The focus was on applying characterization results of a deep learning approach to decisions about clinical CT protocols. MATERIALS AND METHODS. A proprietary deep learning image reconstruction (DLIR) method was characterized against an existing advanced adaptive statistical iterative reconstruction method (ASIR-V) and FBP from the same vendor. The metrics used were contrast-to-noise ratio, spatial resolution as a function of contrast level, noise texture (i.e., noise power spectra [NPS]), noise scaling as a function of slice thickness, and CT number consistency. The American College of Radiology accreditation phantom and a uniform water phantom were used at a range of doses and slice thicknesses for both axial and helical acquisition modes. RESULTS. ASIR-V and DLIR were associated with improved contrast-to-noise ratio over FBP for all doses and slice thicknesses. No dose or contrast dependencies of spatial resolution were observed for ASIR-V or DLIR. NPS results showed DLIR maintained an FBP-like noise texture whereas ASIR-V shifted the NPS to lower frequencies. Noise changed with dose and slice thickness in the same manner for ASIR-V and FBP. DLIR slice thickness noise scaling differed from FBP, exhibiting less noise penalty with decreasing slice thickness. No clinically significant changes were observed in CT numbers for any measurement condition. CONCLUSION. In a phantom model, DLIR does not suffer from the concerns over reduction in spatial resolution and introduction of poor noise texture associated with previous methods.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Szczykutowicz TP, Nett B, Cherkezyan L, et al. Protocol Optimization Considerations for Implementing Deep Learning CT Reconstruction. AJR Am J Roentgenol. 2021. PMID: 33852337. doi:10.2214/AJR.20.23397

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。