文献速递神经介入DSA

血流导向装置治疗不适合弹簧圈栓塞的未破裂ICA分叉部动脉瘤

Flow-Diversion Treatment for Unruptured ICA Bifurcation Aneurysms with Unfavorable Morphology for Coiling.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-04-15

本研究连续纳入20例未破裂ICA分叉部动脉瘤,采用Pipeline血流导向装置从M1段部署至ICA,覆盖动脉瘤及A1段。动脉瘤闭塞与覆盖的A1段血流改变相关,在存在前交通动脉良好侧支代偿时似乎安全。

要点

  • 对于弹簧圈栓塞不利形态的ICA分叉部动脉瘤,M1至ICA的血流导向装置治疗可行。
  • 术后随访中覆盖的A1段出现闭塞或狭窄等血流改变,与动脉瘤闭塞相关。
  • 治疗前需确认经前交通动脉的对侧血流代偿良好,以保障A1段血流改变时的安全性。

关键影像表现/征象

  • 所有患者造影均可见经前交通动脉的对侧血流。
  • 平均动脉瘤大小为6.5 mm(SD 3.2 mm,范围4.5-20 mm)。
  • 覆盖的A1段出现血流改变:10例(50%)闭塞、9例(45%)狭窄、1例(5%)无变化,均无症状。

诊断标准与关键数值

  • 动脉瘤形态不利于弹簧圈栓塞:瘤颈比平均/中位1.6/1.6(范围0.8-2.8,IQR 0.5)或纵横比平均/中位1.5/1.55(范围0.8-2.5,IQR 0.6)。
  • 闭塞的A1段初始平均直径为2.1 mm(SD 0.4 mm,范围1.6-3 mm),狭窄的A1段为2 mm(SD 0.2 mm,范围1.7-2.6 mm),两者无差异。

临床应用与阅片要点

  • 对于ICA分叉部动脉瘤,当瘤颈比或纵横比不利于弹簧圈栓塞时,可考虑M1至ICA的血流导向装置治疗。
  • 术前应评估前交通动脉的对侧血流代偿,确保覆盖A1段后血流改变时仍能维持远端供血。
  • 术后随访需关注覆盖的A1段血流改变(闭塞或狭窄),虽本组均无症状,但仍需监测。

局限性

  • 样本量小(20例),为连续病例系列,非对照研究。
  • 随访时间较短(平均13个月),长期结局未知。
  • 仅纳入存在经前交通动脉对侧血流的患者,结果可能不适用于侧支代偿不良者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Few reports described flow diversion for ICA bifurcation aneurysms. Our aim was to provide further insight into flow diversion for ICA bifurcation aneurysms difficult to treat with other strategies.

MATERIALS AND METHODS: Consecutive patients receiving flow diverters for unruptured ICA bifurcation aneurysms were collected. Aneurysm occlusion (O'Kelly-Marotta grading scale) and clinical outcomes were evaluated.

RESULTS: Twenty saccular ICA bifurcation aneurysms were treated with the Pipeline Embolization Device deployed from the M1 to the ICA, covering the aneurysm and the A1 segment. All patients presented with an angiographic visualized contralateral flow from the anterior communicating artery. Mean aneurysm size was 6.5 (SD, 3.2) mm (range, 4.5-20 mm). All lesions had an unfavorable dome-to-neck ratio (mean/median, 1.6/1.6; range, 0.8-2.8; interquartile range = 0.5) or aspect ratio for coiling (mean/median = 1.5/1.55; range, 0.8-2.5; interquartile range = 0.6). One was a very large aneurysm (20 mm). Nineteen medium-sized lesions were completely occluded during the angiographic follow-up (13 months). No cases of aneurysm rupture or retreatment were reported. No adverse events were described. Aneurysm occlusion was associated with the asymptomatic flow modification of the covered A1 that was occluded and contralaterally filled among 10 patients (50%), narrowed among 9 patients (45%), and unchanged in 1 subject (5%). There was no difference in the mean initial diameter of the occluded (2.1 [SD 0.4] mm; range, 1.6-3 mm) and narrowed (2 [SD, 0.2] mm; range, 1.7-2.6 mm) A1 segments.

CONCLUSIONS: Medium-sized unruptured ICA bifurcation aneurysms with unfavorable morphology for coiling can be treated with M1 ICA flow diversion. Aneurysm occlusion is associated with flow modifications of the covered A1 that seems safe in the presence of a favorable collateral anatomy through the anterior communicating artery complex.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Cagnazzo F, Derraz I, Dargazanli C, et al. Flow-Diversion Treatment for Unruptured ICA Bifurcation Aneurysms with Unfavorable Morphology for Coiling. AJNR Am J Neuroradiol. 2021. PMID: 33858823. doi:10.3174/ajnr.A7125

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。