关节超声、双能CT与微创关节镜诊断膝痛风性关节炎的比较研究
该前瞻性研究纳入121例膝关节肿痛住院患者(63例痛风、58例非痛风),术前均行关节超声和双能CT评估尿酸盐沉积,随后行微创关节镜,以滑液偏振光显微镜或病理发现尿酸盐晶体为金标准。结果显示超声双轨征、高回声灶、双能CT尿酸盐沉积及关节镜尿酸盐沉积(含软骨沉积)与金标准显著相关,除高回声灶外其余指标敏感度和特异度约或超过80%,关节镜优于超声和双能CT,可作为痛风诊断的有用补充。
要点
- 超声双轨征、双能CT尿酸盐沉积及关节镜软骨尿酸盐沉积对膝痛风诊断敏感度和特异度约或超过80%。
- 关节镜诊断膝痛风优于关节超声和双能CT,可作为补充手段。
- 超声高回声灶的诊断效能相对较低,判读时需结合其他征象。
关键影像表现/征象
- 超声双轨征、高回声灶、双能CT尿酸盐沉积、关节镜尿酸盐沉积及关节镜软骨尿酸盐沉积与金标准显著相关。
- 除高回声灶外,其余四项指标敏感度和特异度约或超过80%,OR为14.73至36.56。
- 关节镜软骨尿酸盐沉积与超声双轨征诊断一致性较好(κ=0.711,p<0.001)。
诊断标准与关键数值
- 以滑液偏振光显微镜或病理分析发现尿酸盐晶体为痛风诊断金标准。
- 超声双轨征、双能CT尿酸盐沉积、关节镜尿酸盐沉积及关节镜软骨尿酸盐沉积敏感度和特异度约或超过80%,OR为14.73至36.56。
- 超声高回声灶与金标准显著相关,但除其外其余四项指标具有较高敏感度和特异度。
临床应用与阅片要点
- 膝痛风诊断可联合超声双轨征与双能CT尿酸盐沉积评估,二者均与金标准显著相关。
- 关节镜软骨尿酸盐沉积与超声双轨征一致性较好,可作为超声和双能CT的补充。
- 超声高回声灶单独诊断效能有限,报告时应结合双轨征等其他征象。
局限性
- 单中心前瞻性研究,样本量121例,结论外推需谨慎。
- 微创关节镜为有创检查,不宜作为常规首选筛查手段。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to investigate the diagnostic performance of minimally invasive arthroscopy for knee gout when comparing with joint ultrasonography and dual-energy computed tomography (DECT).
METHODS: From January 2016 to December 2018, 121 inpatients with knee joint swelling and pain were prospectively enrolled, including 63 gout patients and 58 non-gout patients. All patients underwent pre-operative ultrasonography and DECT to evaluate knee joint monosodium urate (MSU) deposits, followed by minimally invasive arthroscopy. The gold-standard for gout diagnosis was defined as the detection of MSU crystals in the synovial fluid under polarizing microscopic or pathological analysis.
RESULTS: The diagnostic results of ultrasonic double contour sign, hyperechogenic foci, MSU deposition (detected by DECT), MSU deposition (detected by arthroscopy) and MSU deposition in cartilage (detected by arthroscopy) were significantly associated with that of the gold-standard. Except for hyperechogenic foci, the other four indexes had high sensitivity and specificity (approximately or over 80%) and a large odds ratio (OR) (14.73 to 36.56), indicating good diagnostic performance. Detection of MSU deposition in cartilage by arthroscopy had a good diagnostic agreement with the ultrasonic double contour sign (κ = 0.711, p < 0.001).
CONCLUSION: Joint ultrasonography, DECT, and minimally invasive arthroscopy had high sensitivity and specificity for the diagnosis of knee gouty arthritis. Minimally invasive arthroscopy was superior to joint ultrasonography and DECT, which can be a useful supplement for the diagnosis of gout.
ADVANCES IN KNOWLEDGE: This is the first study comparing the diagnostic performance for knee gout among the joint ultrasonography, DECT, and minimally invasive arthroscopy.
引用
- Xie Y, Li L, Luo R, et al. Diagnostic efficacy of joint ultrasonography, dual-energy computed tomography and minimally invasive arthroscopy on knee gouty arthritis, a comparative study. Br J Radiol. 2021. PMID: 33861155. doi:10.1259/bjr.20200493
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。