测量髋臼指数:一种准确可靠的替代方法
本研究纳入40例(324髋)4个月至8岁发育性髋关节发育不良评估患儿,比较传统法与替代法测量髋臼指数的准确性和可靠性。替代法平均绝对误差为2.50°,显著低于6°阈值(t<0.001);替代法组内信度ICC为0.92,组间信度ICC为0.91,均高于传统法。结论认为替代法具有很高的准确性和组内、组间信度。
要点
- 替代法以坐骨结节连线为参考,避免三叉软骨线变异带来的测量不确定性。
- 替代法平均绝对误差2.50°,低于预设的6°准确性阈值。
- 替代法组内信度ICC 0.92、组间信度ICC 0.91,均高于传统法。
核心结论
- 使用替代法测量髋臼指数具有很高的准确性以及组内和组间信度。
研究设计与样本
- 研究纳入4个月至8岁因发育性髋关节发育不良评估就诊的儿童,共40例(324髋),平均年龄23.7个月(范围4-96个月)。
- 两名医师分别使用传统法和替代法在所有X线片上测量髋臼指数,准确性定义为平均绝对误差小于6°,信度采用组内相关系数(ICC)计算。
关键影像表现/征象
- 替代法通过连接坐骨结节连线与髋臼下内缘和上外缘连线的夹角来推导髋臼指数,以避免三叉软骨线作为参考点带来的变异性。
诊断标准与关键数值
- 替代法平均绝对误差为2.50°,显著低于6°阈值(t<0.001)。
- 传统法组内信度ICC为0.81,替代法组内信度ICC为0.92。
- 传统法组间信度ICC为0.89,替代法组间信度ICC为0.91。
- 平均髋臼指数为24.2°(范围8-50°)。
临床应用与阅片要点
- 在儿童髋关节X线评估中,可考虑采用基于坐骨结节的替代法测量髋臼指数,以减少因三叉软骨线识别困难导致的测量变异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. In children (4 months to 8 years old), radiographic measurements of the acetabular index are the preferred method to assess developmental hip dysplasia. However, the acetabular index has been criticized as having variable reliability owing to difficulty identifying the correct anatomic landmarks. An alternative method of measuring the acetabular index using the ischium is being proposed to avoid the variability of the triradiate cartilage line as a reference point. With the alternative method, the acetabular index is derived by measuring the angle between a line connecting the ischial tuberosi-ties and a line connecting the inferomedial and superolateral edges of the acetabulum. The purpose of this study was to evaluate the accuracy and reliability of this alternative method of measuring the acetabular index compared with the traditional method. MATERIALS AND METHODS. Children 4 months to 8 years old who presented for evaluation of developmental dysplasia of the hip were included. Two physicians, each using both the traditional and the alternative method, measured acetabular indexes on all radiographs. Accuracy was defined as mean absolute error less than 6°. Reliability was calculated by means of intraclass correlation coefficient (ICC). RESULTS. Pelvic radiographs of 40 children (324 hips) were included. The mean age was 23.7 months (range, 4-96 months) and mean acetabular index was 24.2° (range, 8-50°). The alternative method was associated with mean absolute error of 2.50°, which is significantly below the threshold of 6° (t < 0.001). Intrarater reliability for the traditional method was high (ICC, 0.81) and for the alternative method was very high (ICC, 0.92). Interrater reliability for the traditional method was high (ICC, 0.89) and for the alternative method was very high (ICC, 0.91). CONCLUSION. Measuring the acetabular index using the alternative method has very high accuracy and intrarater and interrater reliability.
引用
- Sherman B, Lalonde FD, Schlechter JA, et al. Measuring the Acetabular Index: An Accurate and Reliable Alternative Method of Measurement. AJR Am J Roentgenol. 2021. PMID: 33909466. doi:10.2214/AJR.20.23358
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。