本研究纳入100例同时接受膝关节正位(AP)和Rosenberg位X线检查的患者,由两名观察者独立、间隔8周两次使用Kellgren & Lawrence(K&L)、IKDC、Ahlbäck和Fairbank四种分级系统进行评估。结果显示IKDC信度最高(观察者间0.79、观察者内0.86),Fairbank最低(0.20和0.27);Rosenberg位对重度OA的检出总体比AP位更敏感;所有分级系统与Oxford膝关节评分(OKS)均无统计学显著相关性。

要点

  • IKDC分级系统在四种系统中观察者间与观察者内信度最高,Fairbank最低。
  • Rosenberg位对重度膝关节OA的检出总体比AP位更敏感。
  • 影像学分级结果与患者报告的OKS症状严重程度无显著相关性。

诊断标准与关键数值

  • IKDC观察者间信度0.79、观察者内信度0.86,为四种系统中最高。
  • Fairbank观察者间信度0.20、观察者内信度0.27,为四种系统中最低。
  • AP位与Rosenberg位在四种分级系统间均存在显著差异(p < 0.001)。
  • 四种分级系统与Oxford膝关节评分(OKS)均无统计学显著相关性。

临床应用与阅片要点

  • 日常阅片中可优先考虑使用IKDC分级系统,因其观察者间与观察者内信度最高。
  • 评估重度膝关节OA时,Rosenberg位较AP位总体更敏感,建议结合两种体位。
  • 影像学分级结果不应单独用于推断患者症状严重程度,需结合临床。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: Radiographs are the first-line investigation for knee osteoarthritis (OA). Antero-posterior (AP) and Rosenberg views have demonstrated varying sensitivities in detecting severe OA. There is a multitude of radiological grading systems described. The aim of this study was to assess four commonly used grading systems in terms of inter- and intra-observer reliability and correlate the results with patient-reported symptom severity.

MATERIALS AND METHODS: This study included 100 patients who had undergone both AP and Rosenberg X-ray views of the knee and evaluated using four radiological grading systems. These included Kellgren & Lawrence (K&L), International Knee Documentation Committee (IKDC), Ahlbäck and Fairbank. Evaluations were performed by two observers, independently, at two separate time points, 8 weeks apart. The data was then statistically analysed and inter- and intra-observer reliability calculated.

RESULTS: A significant difference was found between AP and Rosenberg views for all four grading systems (p < 0.001). Both inter- and intra-observer reliability were highest for IKDC (0.79 and 0.86 respectively) and lowest for Fairbank (0.20 and 0.27 respectively). No statistically significant correlation was found between any grading system and the Oxford knee score (OKS).

CONCLUSION: IKDC was found to be the most reliable grading system and Fairbank was the least. The Rosenberg view was overall more sensitive at detecting severe OA than the AP view. Radiological findings did not correlate with patient-reported symptoms (OKS).