文献速递甲状腺与浅表US

超声哪个图像切面适合评估甲状腺结节风险分层中的纵横比大于1征象

Which ultrasound image plane is appropriate for evaluating the taller-than-wide sign in the risk stratification of thyroid nodules?
PubMed 文献 · Eur Radiol · 2021-04-14

研究纳入1905个连续甲状腺结节,前瞻性在横切面和纵切面评估纵横比大于1征象,比较该征象及五种风险分层系统活检标准的诊断效能。横切面与横切面或纵切面任一显示纵横比大于1两种标准的敏感度、特异度和AUC均无显著差异,横切面标准可能适合用于甲状腺结节风险分层。

要点

  • 横切面标准与横切面或纵切面任一标准诊断恶性结节的AUC分别为0.662和0.665,差异无统计学意义(p=0.158)。
  • 两种纵横比大于1标准敏感度37.5%对38.7%、特异度94.8%对94.4%,差异极小。
  • 结节≥1 cm时,五种风险分层系统活检标准的诊断效能两种标准间均无显著差异(p≥0.157、p≥0.317、p≥0.198)。

核心结论

  • 横切面标准(标准1)与横切面或纵切面任一标准(标准2)评估纵横比大于1征象及五种风险分层系统活检标准的诊断效能相似,横切面标准可能适合用于甲状腺结节风险分层。

研究设计与样本

  • 前瞻性评估1905个连续甲状腺结节的纵横比大于1征象,在横切面和纵切面超声图像上分别评估,以最终诊断为标准,比较两种切面标准下该征象及五种广泛使用风险分层系统活检标准的诊断效能。

关键影像表现/征象

  • 纵横比大于1征象定义为结节前后径大于横径,在横切面和纵切面超声图像上前瞻性评估。
  • 全部1905个结节中良性1481个(77.7%),恶性424个(22.3%)。

诊断标准与关键数值

  • 标准1(横切面)纵横比大于1征象诊断恶性的敏感度37.5%、特异度94.8%、AUC 0.662。
  • 标准2(横切面或纵切面任一)纵横比大于1征象诊断恶性的敏感度38.7%、特异度94.4%、AUC 0.665。
  • 两种标准AUC比较p=0.158,差异无统计学意义。
  • 结节≥1 cm时,五种风险分层系统活检标准的敏感度、特异度和AUC在两种标准间均无显著差异(敏感度p≥0.157、特异度p≥0.317、AUC p≥0.198)。

临床应用与阅片要点

  • 作者认为横切面评估纵横比大于1征象可能适合用于甲状腺结节风险分层。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to determine the ultrasound (US) image plane appropriate for evaluating the taller-than-wide (TTW) sign in the risk stratification of thyroid nodules using the five widely used risk stratification systems (RSSs).

METHODS: A total of 1905 consecutive thyroid nodules with final diagnoses were included. The TTW sign was prospectively assessed in the transverse and longitudinal US image planes. The diagnostic performances of the TTW sign and biopsy criteria by the RSSs for malignancy were compared by sensitivity, specificity, and receiver operating characteristic curve analysis between the two criteria of TTW signs according to image planes (criterion 1, transverse plane; criterion 2, either transverse or longitudinal plane).

RESULTS: Of all 1905 nodules, 1481 (77.7%) were benign and 424 (22.3%) were malignant. The criteria 1 and 2 of TTW signs had similar sensitivities (37.5% and 38.7%) and specificities (94.8% and 94.4%) with minimal differences, and the area under the curve (AUC) of TTW signs for malignancy was not significantly different between criteria 1 and 2 (0.662 and 0.665, p = 0.158, respectively). The sensitivity, specificity, and AUC of biopsy criteria by the five RSSs were not significantly different between criteria 1 and 2 in nodules ≥ 1 cm (p ≥ 0.157, p ≥ 0.317, and p ≥ 0.198, respectively).

CONCLUSIONS: The diagnostic performances of the TTW sign and biopsy criteria of the five RSSs were similar between criteria 1 and 2. TTW signs by criterion 1 (transverse plane) may be appropriate in the risk stratification of thyroid nodules.

KEY POINTS: • The diagnostic performance of the taller-than-wide sign by ROC analysis was not significantly different between US image plane criteria (transverse plane vs. either transverse or longitudinal plane). • The diagnostic performances of biopsy criteria for malignancy by the five risk stratification systems were similar between the two taller-than-wide sign criteria. • The taller-than-wide sign using the transverse plane may be appropriate in the risk stratification of thyroid nodules.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kim SY, Na DG, Paik W, et al. Which ultrasound image plane is appropriate for evaluating the taller-than-wide sign in the risk stratification of thyroid nodules? Eur Radiol. 2021. PMID: 33855586. doi:10.1007/s00330-021-07936-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。