14G半自动针芯活检用于乳腺Paget病组织学诊断的新技术
本研究回顾性纳入26例临床怀疑Paget病的乳头-乳晕复合体改变女性,采用14G半自动针芯活检(N-CNB)行组织学诊断。13/26例确诊为Paget病,均经手术标本组织学证实;良性结果者随访未发现恶性病变,无显著活检后并发症。Paget病患者更常出现乳头回缩及BI-RADS 4/5类钼靶表现。
要点
- 乳头-乳晕复合体可疑Paget病可采用14G半自动针芯活检获取组织学诊断。
- Paget病患者更常伴乳头回缩和BI-RADS 4/5类钼靶异常。
- 该技术操作简便、无痛、无重大并发症,良性结果随访未漏诊恶性。
关键影像表现/征象
- Paget病患者较N-CNB良性结果者更常出现乳头回缩(ρ=0.0407)。
- Paget病患者更常伴可疑钼靶表现(BI-RADS 4和5类)(ρ=0.0006)。
- N-CNB后无显著活检后并发症记录。
诊断标准与关键数值
- N-CNB后13/26例(50%)组织学诊断为Paget病,13/26例(50%)为良性改变。
- 13例N-CNB诊断的Paget病均经手术标本组织学分析确认。
- 良性N-CNB结果者随访期间未检出恶性病变。
临床应用与阅片要点
- 对临床怀疑Paget病的乳头-乳晕复合体改变,可考虑14G半自动针芯活检获取组织学诊断。
- 阅片时注意乳头回缩及BI-RADS 4/5类钼靶表现,提示Paget病可能性更高。
- 活检操作在麻醉及冰敷后以14G针具对乳头-乳晕复合体施压定位,每次移动针位获取2-4条组织。
局限性
- 回顾性单中心分析,样本量26例。
- 原文未报告敏感度、特异度、AUC等诊断效能指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of our work is to illustrate a new technique for the histological diagnosis of Paget's disease (PD) using a core needle biopsy with a semiautomated 14-gauge needle called nipple-core needle biopsy (N-CNB). We report 3 years' experience in our senology unit.
MATERIALS AND METHODS: Twenty-six women with 26 clinical of nipple-areola complex (NAC) changes with suspected PD and subjected to core needle biopsy using our new 14G semiautomated needle technique were included in our study group. Institutional review board approval was obtained for this retrospective analysis. A semiautomated biopsy gun with a 14-gauge, 15-cm-long needle was used for this new procedure. After a subcutaneous injection of anesthetic and spray-ice application to the NAC, the 14G needle was opened with the cradle exposed and positioned on the NAC with considerable pressure exerted on the same. The cradle was then closed by triggering the needle spring, and 2-4 core samples were withdrawn by moving the needle position each time. Clinical, instrumental and histological differences between the lesions that gave benign results after N-CNB and those that resulted PD were analyzed by applying the Fisher's exact test.
RESULTS: After N-CNB, 13/26 lesions were found to be PD (50%) while 13/26 alterations were benign (50%). No malignant lesions were detected during the follow-up in patients with benign N-CNB results. The diagnosis of PD obtained with N-CNB was confirmed in all 13 cases by means of a histological analysis of the surgical specimens. No significant post-biopsy complications were recorded. Patients with PD more frequently presented nipple retraction (ρ = 0.0407) and associated suspicious (i.e., BI-RADS 4 and 5) mammographic (ρ = 0.0006) findings compared to patients whose N-CNB had given benign results and the difference was statistically significant.
CONCLUSIONS: In conclusion, with this novel technique, we were able to obtain an easy, painless, major complication-free and accurate diagnosis of PD of the NAC using a semiautomated core needle biopsy with a 14-gauge needle.
引用
- Nori J, Bicchierai G, Amato F, et al. A new technique for the histological diagnosis of Paget's disease of the breast using a semiautomated core needle biopsy with a 14-gauge needle. Radiol Med. 2021. PMID: 33900526. doi:10.1007/s11547-021-01358-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。