钙化性小叶内瘤变与偶然非钙化性经典型小叶内瘤变的升级率管理
该回顾性研究分析390例因可疑钙化行立体定向核芯针活检的病例,其中81例最高风险病变为小叶内瘤变。钙化性小叶内瘤变手术升级率为20.0%(3/15),而非钙化偶然性小叶内瘤变升级率仅2.4%(1/42),且未手术随访组未发现癌症。结论提示非钙化偶然性经典型小叶内瘤变可影像随访,而钙化性小叶内瘤变应手术切除。
要点
- 钙化性小叶内瘤变升级率20.0%,应建议手术切除。
- 非钙化偶然性经典型小叶内瘤变升级率2.4%,可影像随访。
- 影像-病理一致性评估是避免漏诊的关键。
关键影像表现/征象
- 81例小叶内瘤变中16例病变内见钙化,其中15例手术切除。
- 64例为非钙化偶然性小叶内瘤变伴良性一致病变(含钙化),其中42例手术切除。
- 1例影像-病理不一致行切除,证实为浸润性癌(管状小叶和小叶特征)。
诊断标准与关键数值
- 升级定义为手术切除证实为导管原位癌或浸润性导管/小叶癌。
- 钙化性小叶内瘤变升级率20.0%(3/15)。
- 非钙化偶然性小叶内瘤变升级率2.4%(1/42)。
临床应用与阅片要点
- 报告小叶内瘤变时需描述是否伴钙化及有无良性一致病变解释靶钙化。
- 非钙化偶然性经典型小叶内瘤变伴良性一致病变可建议影像随访。
- 钙化性小叶内瘤变应建议手术切除。
- 注意影像-病理不一致时需切除,避免漏诊浸润性癌。
局限性
- 回顾性单中心研究,样本量有限。
- 部分病例选择影像随访而非手术切除,可能存在验证偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of our study was to evaluate the upgrade rate of calcified lobular neoplasia (LN) versus incidental noncalcified classic LN found on core needle biopsy performed for the evaluation of suspicious calcifications. MATERIALS AND METHODS. This retrospective study included 390 consecutive image-guided breast core needle biopsies with microcalcifications as the target that were performed between December 2009 and July 2017. In 81 of the 390 core biopsies, the highest-risk lesion was LN that then underwent either excision or imaging follow-up. Core biopsy results were compared with excision and imaging follow-up findings. An upgrade of LN was defined as ductal carcinoma in situ or invasive ductal or lobular carcinoma. RESULTS. Of 81 LN diagnosed on core biopsy performed for calcifications, 16 had calcifications within the LN. Fifteen of these 16 cases underwent surgical excision, and three (3/15, 20.0%) were upgraded on excision. Of the 64 core biopsies showing incidental noncalcified LN with benign concordant entities containing calcifications, 42 underwent surgical excision, and one LN (1/42, 2.4%) was upgraded. Twenty-three total lesions (one calcified LN and 22 noncalcified LN) were followed with imaging rather than excision. No cancers were detected among the follow-up group. One case was deemed to have discordant findings on radiologic-pathologic review and was sent for excision, which showed invasive cancer with tubulolobular and lobular features. CONCLUSION. Women undergoing stereotactic core needle biopsy for calcifications revealing noncalcified incidental classic LN and a benign concordant entity that could explain the presence of the target calcifications have a low risk of upgrade and may be followed with imaging. Surgical excision should be offered to women who have LN with calcifications.
引用
- Kunjummen J, Rodriguez K, Newell MS, et al. Management of Lobular Neoplasia Found on Core Needle Biopsy Performed for Calcifications Using Precise Radiologic-Pathologic Correlation. AJR Am J Roentgenol. 2021. PMID: 33852331. doi:10.2214/AJR.19.22599
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。