文献速递乳腺CT

乳腺癌放疗腋窝淋巴结临床靶区几何轮廓差异:AIRO多中心研究

Geometric contour variation in clinical target volume of axillary lymph nodes in breast cancer radiotherapy: an AIRO multi-institutional study.
PubMed 文献 · Br J Radiol · 2021-04-21

各中心勾画的腋窝CTV与金标准CTV存在实质性差异,尤其手臂摆位改变时。

要点

  • 腋窝淋巴结勾画在L2和L3水平变异最大,报告时需特别关注。
  • 手臂摆位改变时靶区勾画差异更显著。
  • 所有病例DICE相似系数均未达到0.70的一致性阈值。

核心结论

  • 各中心勾画的腋窝CTV与金标准CTV存在实质性差异,尤其手臂摆位改变时。
  • L2和L3淋巴结水平是勾画最关键的部位,需重点改进。
  • 几何不确定性可能导致剂量学错误并影响肿瘤学结局。

研究设计与样本

  • 金标准CTV由乳腺癌专家勾画的腋窝CTV中位轮廓生成,经STAPLE验证和同行评审。
  • 各中心放疗医师勾画的SC-CTV与GS-CTV使用验证的几何指标及总分进行比较。

诊断标准与关键数值

  • SC-CTV与GS-CTV比较:P1平均小29.25%,P2平均小27.83%,P3平均大12.53%。
  • 平均Jaccard指数P1和P2高于P3,但重叠范围值约0.50或更低。
  • 淋巴结水平中L4与GS一致性最高;患者内比较L2和L3总分低于L4。
  • 所有测量中DICE相似系数均未超过一致性最低阈值0.70。

临床应用与阅片要点

  • 日常勾画腋窝淋巴结CTV时应特别关注L2和L3水平,减少观察者间变异。
  • 手臂摆位改变时需注意靶区几何轮廓可能发生显著变化。
  • 报告或勾画时应参考统一标准以减少几何不确定性对剂量学的影响。

局限性

  • 仅纳入3例患者,样本量小。
  • 金标准CTV基于专家中位轮廓生成,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine interobserver variability in axillary nodal contouring in breast cancer (BC) radiotherapy (RT) by comparing the clinical target volume of participating single centres (SC-CTV) with a gold-standard CTV (GS-CTV).

METHODS: The GS-CTV of three patients (P1, P2, P3) with increasing complexity was created in DICOM format from the median contour of axillary CTVs drawn by BC experts, validated using the simultaneous truth and performance-level estimation and peer-reviewed. GS-CTVs were compared with the correspondent SC-CTVs drawn by radiation oncologists, using validated metrics and a total score (TS) integrating all of them.

RESULTS: Eighteen RT centres participated in the study. Comparative analyses revealed that, on average, the SC-CTVs were smaller than GS-CTV for P1 and P2 (by -29.25% and -27.83%, respectively) and larger for P3 (by +12.53%). The mean Jaccard index was greater for P1 and P2 compared to P3, but the overlap extent value was around 0.50 or less. Regarding nodal levels, L4 showed the highest concordance with the GS. In the intra-patient comparison, L2 and L3 achieved lower TS than L4. Nodal levels showed discrepancy with GS, which was not statistically significant for P1, and negligible for P2, while P3 had the worst agreement. DICE similarity coefficient did not exceed the minimum threshold for agreement of 0.70 in all the measurements.

CONCLUSIONS: Substantial differences were observed between SC- and GS-CTV, especially for P3 with altered arm setup. L2 and L3 were the most critical levels. The study highlighted these key points to address.

ADVANCES IN KNOWLEDGE: The present study compares, by means of validated geometric indexes, manual segmentations of axillary lymph nodes in breast cancer from different observers and different institutions made on radiotherapy planning CT images. Assessing such variability is of paramount importance, as geometric uncertainties might lead to incorrect dosimetry and compromise oncological outcome.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Leonardi MC, Pepa M, Gugliandolo SG, et al. Geometric contour variation in clinical target volume of axillary lymph nodes in breast cancer radiotherapy: an AIRO multi-institutional study. Br J Radiol. 2021. PMID: 33882239. doi:10.1259/bjr.20201177

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。