数字乳腺断层摄影筛查中压迫力与早期性能指标的关系
该研究基于挪威乳腺癌筛查项目中25,286名接受数字乳腺断层摄影(DBT)筛查的女性,分析压迫力与压力对共识率、召回率和筛查检出乳腺癌率的影响。结果显示最高筛查检出癌率见于低压迫力和低压力组,但调整回归分析中连续压迫力或压力与早期性能指标无显著关联。
要点
- DBT筛查中压迫力与筛查性能指标的关联不显著,与标准数字乳腺摄影的报道不同。
- 低压迫力(CC<82.5N,MLO<92.0N)和低压力(MLO<7.2kPa)组筛查检出癌率最高。
- 日常阅片报告可关注压迫力参数,但不应仅凭低压迫力判断筛查性能下降。
诊断标准与关键数值
- CC位平均压迫力90.8 N(SD=14.2),MLO位106.3 N(SD=20.6);CC位平均压力11.3 kPa(SD=3.6),MLO位8.7 kPa(SD=2.0)。
- 筛查检出癌率最高见于CC位压迫力<82.5 N(1.04%)和MLO位<92.0 N(1.07%),以及MLO位压力<7.2 kPa(1.07%)。
临床应用与阅片要点
- DBT筛查中压迫力或压力与早期性能指标的关联不显著,阅片报告时可结合压迫力参数但不作为独立预测因素。
- 低压迫力和低压力组筛查检出癌率较高,但需注意避免因低压迫力而过度召回或漏诊。
局限性
- 研究为观察性设计,无法确定因果关系。
- 未报告其他潜在混杂因素如乳腺密度分层外的个体差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We aimed to determine if compression force or pressure could be associated with early performance measures for women screened with digital breast tomosynthesis (DBT) in BreastScreen Norway. Early performance measures included rates of consensus, recall, and screen-detected breast cancer.
METHOD: Data on compression force and pressure, compressed breast thickness and breast characteristics were extracted from an automated software for density assessment of DBT screening examinations for 25,286 women. For descriptive analyses, force (Newton, N) and pressure (kilopascal, kPa) were categorized into quartiles. Analyses were stratified by mammographic view, craniocaudal (CC) and mediolateral oblique (MLO). Logistic regression with restricted cubic splines was used to investigate the association between force and pressure as continuous exposures and early performance measures adjusted for age, compressed breast thickness and fibroglandular volume.
RESULTS: Mean age of the screened women was 60.7 (SD = 5.2) years. Mean compression force was 90.8 (SD = 14.2) N for CC and 106.3 (SD = 20.6) N for MLO, and pressure was 11.3 (SD = 3.6) kPa for CC and 8.7 (SD = 2.0) kPa for MLO. The highest rates of screen-detected cancer were observed for low force (1.04 % for <82.5 N for CC and 1.07 % for <92.0 N for MLO) and low pressure (1.07 % for <7.2 kPa for MLO). No association was found between force or pressure as continuous exposures and early performance measures in adjusted regression analyses.
CONCLUSIONS: We found the highest rates of screen-detected cancer for low force and pressure, but no significant association between continuous values of force or pressure and early performance measures in DBT. The findings might indicate that the levels of force and pressure in DBT are of lower significance for screening performance than reported in standard digital mammography.