文献速递乳腺MR

面向术前乳腺癌患者MRI引导活检的计算机辅助分诊研究

Toward Computer-Assisted Triaging of Magnetic Resonance Imaging-Guided Biopsy in Preoperative Breast Cancer Patients.
PubMed 文献 · Invest Radiol · 2021-01-01

本研究开发了一种多参数CAD模型,用于术前乳腺癌患者MRI额外病灶的活检分诊。在训练集中,模型在98%特异度下正确识别48%的恶性病灶;独立测试集在98%特异度工作点下敏感度为44%。模型显示出接近完美特异度识别恶性病变扩展的潜力,可对约半数患者进行分诊。

要点

  • 多参数CAD模型可在98%特异度下识别约半数恶性额外病灶。
  • 模型校准良好,在独立测试集中特异度达96%时敏感度44%。
  • 该模型有望辅助MRI引导活检分诊,减少不必要的活检。

局限性

  • 单中心回顾性研究。
  • 测试集敏感度低于训练集,存在泛化性能下降。
  • 模型仅基于影像组学特征,未纳入其他临床信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Incidental MR-detected breast lesions (ie, additional lesions to the index cancer) pose challenges in the preoperative workup of patients with early breast cancer. We pursue computer-assisted triaging of magnetic resonance imaging (MRI)-guided breast biopsy of additional lesions at high specificity.

MATERIALS AND METHODS: We investigated 316 consecutive female patients (aged 26 to 76 years; mean, 54 years) with early breast cancer who received preoperative multiparametric breast MRI between 2013 and 2016. In total, 82 (26%) of 316 patients had additional breast lesions on MRI. These 82 patients had 101 additional lesions in total, 51 were benign and 50 were malignant. We collected 4 clinical features and 46 MRI radiomic features from T1-weighted dynamic contrast-enhanced imaging, high-temporal-resolution dynamic contrast-enhanced imaging, T2-weighted imaging, and diffusion-weighted imaging. A multiparametric computer-aided diagnosis (CAD) model using 10-fold cross-validated ridge regression was constructed. The sensitivities were calculated at operating points corresponding to 98%, 95%, and 90% specificity. The model calibration performance was evaluated by calibration plot analysis and goodness-of-fit tests. The model was tested in an independent testing cohort of 187 consecutive patients from 2017 and 2018 (aged 35 to 76 years; mean, 59 years). In this testing cohort, 45 (24%) of 187 patients had 55 additional breast lesions in total, 23 were benign and 32 were malignant.

RESULTS: The multiparametric CAD model correctly identified 48% of the malignant additional lesions with a specificity of 98%. At specificity 95% and 90%, the sensitivity was 62% and 72%, respectively. Calibration plot analysis and goodness-of-fit tests indicated that the model was well fitted.In the independent testing cohort, the specificity was 96% and the sensitivity 44% at the 98% specificity operating point of the training set. At operating points 95% and 90%, the specificity was 83% at 69% sensitivity and the specificity was 78% at 81% sensitivity, respectively.

CONCLUSIONS: The multiparametric CAD model showed potential to identify malignant disease extension with near-perfect specificity in approximately half the population of preoperative patients originally indicated for a breast biopsy. In the other half, patients would still proceed to MRI-guided biopsy to confirm absence of malignant disease. These findings demonstrate the potential to triage MRI-guided breast biopsy.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Wang H, van der Velden BHM, Ragusi MAA, et al. Toward Computer-Assisted Triaging of Magnetic Resonance Imaging-Guided Biopsy in Preoperative Breast Cancer Patients. Invest Radiol. 2021. PMID: 33851810. doi:10.1097/RLI.0000000000000759

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。