文献速递妇产影像US

臀位进展角:评估胎儿臀位在产道下降的新经会阴超声参数

Breech progression angle: new feasible and reliable transperineal ultrasound parameter for assessment of fetal breech descent in birth canal.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

本研究纳入44例34-41周臀位单胎孕妇,经会阴超声测量臀位进展角(BPA),评估其可行性与可重复性。结果显示BPA测量成功率高,观察者内和观察者间ICC分别为0.88和0.83,一致性好,无系统偏差,临床因素不影响可靠性。BPA是评估臀位下降的新可行且高度可重复的参数。

要点

  • BPA是评估臀位胎儿在产道下降的新经会阴超声参数,测量可行且可重复性高。
  • 观察者内ICC 0.88,观察者间ICC 0.83,一致性好,无系统偏差。
  • 产妇BMI、年龄、孕周和产次不影响BPA测量的可靠性。

核心结论

  • BPA是评估臀位胎儿在产道下降的新可行且高度可重复的测量参数。
  • 未来需研究BPA在预测外倒转术成功和臀位阴道分娩中的价值。

研究设计与样本

  • 前瞻性研究,纳入44例34-41周臀位单胎孕妇,经会阴超声获取正中矢状面图像。
  • 每例孕妇由一名操作者采集两次图像、另一名操作者采集一次,匿名后分别测量BPA。
  • 采用ICC评估观察者内和观察者间可重复性,Bland-Altman分析评估一致性,t检验和Levene检验分析临床因素的影响。

关键影像表现/征象

  • BPA定义为沿耻骨联合长轴的线与从耻骨联合最下缘切向胎儿最低可识别部分的线之间的角度。
  • 两名操作者对所有图像均成功测量BPA。

诊断标准与关键数值

  • 观察者内ICC为0.88(95% CI 0.80-0.93),观察者间ICC为0.83(95% CI 0.71-0.90)。
  • 观察者内平均差异0.4°(95% CI -1.4至2.2°),观察者间平均差异-0.4°(95% CI -2.6至1.8°)。
  • 观察者内一致性上限12.0°(95% CI 8.9-15.1°),下限-11.2°(95% CI -14.3至-8.1°)。
  • 观察者间一致性上限13.6°(95% CI 9.9-17.3°),下限-14.4°(95% CI -18.2至-10.7°)。
  • 未发现观察者内或观察者间BPA测量存在系统差异;产妇BMI、年龄、孕周和产次对可靠性无显著影响。

临床应用与阅片要点

  • 经会阴超声正中矢状面测量BPA,操作简单,可作为评估臀位下降的客观工具。
  • 测量时需清晰显示耻骨联合长轴及胎儿最低可识别部分,以确保角度准确。

局限性

  • 样本量较小(44例),仅为方法学研究,尚未验证BPA对临床结局的预测价值。
  • 研究未评估BPA与臀位阴道分娩或外倒转术成功的关联。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the feasibility and reliability of transperineal ultrasound in the assessment of fetal breech descent in the birth canal, by measuring the breech progression angle (BPA).

METHODS: Women with a singleton pregnancy with the fetus in breech presentation between 34 and 41 weeks' gestation were recruited. Transperineal ultrasound images were acquired in the midsagittal view for each woman, twice by one operator and once by another. Each operator measured the BPA after anonymization of the transperineal ultrasound images. BPA was defined as the angle between a line running along the long axis of the pubic symphysis and another line extending from the most inferior portion of the pubic symphysis tangentially to the lowest recognizable fetal part in the maternal pelvis. Each operator was blinded to all other measurements performed for each woman. Intra- and interobserver reproducibility of BPA measurement was evaluated using the intraclass correlation coefficient (ICC). To investigate the presence of any bias, intra- and interobserver agreement was also analyzed using Bland-Altman analysis. Student's t-test and Levene's W0 test were used to investigate whether a number of different clinical factors had an effect on systematic differences and homogeneity, respectively, between BPA measurements.

RESULTS: Overall, 44 women were included in the analysis. BPA was measured successfully by both operators on all images. Both intra- and interobserver agreement analyses showed excellent reproducibility in BPA measurement, with ICCs of 0.88 (95% CI, 0.80-0.93) and 0.83 (95% CI, 0.71-0.90), respectively. The mean difference between measurements was 0.4° (95% CI, -1.4 to 2.2°) for intraobserver repeatability and -0.4° (95% CI, -2.6 to 1.8°) for interobserver repeatability. The upper limits of agreement were 12.0° (95% CI, 8.9-15.1°) and 13.6° (95% CI, 9.9-17.3°) for intra- and interobserver repeatability, respectively. The lower limits of agreement were -11.2° (95% CI, -14.3 to -8.1°) and -14.4° (95% CI, -18.2 to -10.7°) for intra- and interobserver repeatability, respectively. No systematic difference between BPA measurements was found on either intra- or interobserver agreement analysis. None of the clinical factors examined (maternal body mass index, maternal age, gestational age at the ultrasound scan and parity) showed a statistically significant effect on intra- or interobserver reliability.

CONCLUSIONS: BPA represents a new feasible and highly reproducible measurement for the evaluation of fetal breech descent in the birth canal. Future studies assessing its usefulness in the prediction of successful external cephalic version and breech vaginal delivery are needed. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Youssef A, Brunelli E, Fiorentini M, et al. Breech progression angle: new feasible and reliable transperineal ultrasound parameter for assessment of fetal breech descent in birth canal. Ultrasound Obstet Gynecol. 2021. PMID: 33847431. doi:10.1002/uog.23649

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。