文献速递妇产影像腹部MR

迭代去噪三维T2加权涡轮自旋回波用于深部浸润型子宫内膜异位症诊断的评估

Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis.
PubMed 文献 · Invest Radiol · 2021-01-01

ID算法显著改善3D-T2图像质量并减少伪影,3D-T2去噪序列对DIE的诊断观察者间一致性达0.84,扫描时间从7分43秒降至4分58秒且不损害图像质量或诊断信息。

要点

  • 3D-T2去噪序列扫描仅4分58秒,较2D-T2的7分43秒显著缩短,图像质量与诊断信息不劣于2D序列。
  • ID重建显著改善3D-T2图像质量并减少伪影(P<0.001),对DIE诊断的观察者间一致性为0.84。
  • 各DIE定位的观察者间和观察者内一致性在3D-T2去噪与2D-T2序列上均达几乎完美或实质性水平。

局限性

  • 仅一名放射科医师发现3D-T2-denoised较2D-T2图像质量显著改善(P=0.002),另一名阅片者无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The primary end point of this study was to evaluate the image quality and reliability of a highly accelerated 3-dimensional T2 turbo spin echo (3D-T2-TSE) sequence with prototype iterative denoising (ID) reconstruction compared with conventional 2D T2 sequences for the diagnosis of deep infiltrating endometriosis (DIE). The secondary end point was to demonstrate the 3D-T2-TSE sequence image quality improvement using ID reconstruction.

MATERIAL AND METHODS: Patients were prospectively enrolled to our institution for pelvis magnetic resonance imaging because of a suspicion of endometriosis over a 4-month period. Both conventional 2D-T2 (sagittal, axial, coronal T2 oblique to the cervix) and 3D-T2-TSE sequences were performed with a scan time of 7 minutes 43 seconds and 4 minutes 58 seconds, respectively. Reconstructions with prototype ID (3D-T2-denoised) and without prototype ID (3D-T2) were generated inline at the end of the acquisition. Two radiologists independently evaluated the image quality of 3D-T2, 3D-T2-denoised, and 2D-T2 sequences. Diagnosis confidence of DIE was evaluated for both 3D-T2-denoised and 2D-T2 sequences. Intraobserver and interobserver agreements were calculated using Cohen κ coefficient.

RESULTS: Ninety female patients were included. Both readers found that the ID algorithm significantly improved the image quality and decreased the artifacts of 3D-T2-denoised compared with 3D-T2 sequences (P < 0.001). A significant image quality improvement was found by 1 radiologist for 3D-T2-denoised compared with 2D-T2 sequences (P = 0.002), whereas the other reader evidenced no significant difference. The interobserver agreement of 3D-T2-denoised and 2D-T2 sequences was 0.84 (0.73-0.95) and 0.78 (0.65-0.9), respectively, for the diagnosis of DIE. Intraobserver agreement for readers 1 and 2 was 0.86 (0.79-1) and 0.83 (0.76-1), respectively. For all localization of DIE, interobserver and intraobserver agreements were either almost perfect or substantial for both 3D-T2-denoised and 2D-T2 sequences.

CONCLUSIONS: Three-dimensional T2-denoised imaging is a promising tool to replace conventional 2D-T2 sequences, offering a significant scan time reduction without compromising image quality or diagnosis information for the assessment of DIE.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Florin M, Vaussy A, Macron L, et al. Evaluation of Iterative Denoising 3-Dimensional T2-Weighted Turbo Spin Echo for the Diagnosis of Deep Infiltrating Endometriosis. Invest Radiol. 2021. PMID: 33813570. doi:10.1097/RLI.0000000000000786

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。