联合ADC直方图分析与VI-RADS预测膀胱癌肌层浸润
回顾性分析80例膀胱癌患者(NMIBC 53例,MIBC 27例),基于DWI评估VI-RADS并计算体积ADC直方图参数。VI-RADS鉴别MIBC的AUC为0.88,敏感度88.89%,特异度83.61%;VI-RADS联合偏度可提高AUC至0.923。
要点
- VI-RADS鉴别MIBC的AUC为0.88,敏感度88.89%,特异度83.61%。
- MIBC的ADC均值、中位数及多个百分位数低于NMIBC。
- VI-RADS联合ADC偏度可提高诊断效能(AUC 0.923)。
核心结论
- 体积ADC直方图分析和VI-RADS均有助于鉴别MIBC与NMIBC,且直方图分析可为VI-RADS提供附加价值。
研究设计与样本
- 回顾性研究,纳入80例经病理证实为NMIBC(n=53)或MIBC(n=27)的患者,所有患者接受MRI检查包括DWI(b=0, 800 s/mm2),基于DWI评估VI-RADS并计算体积ADC直方图参数,参考标准为病理。
关键影像表现/征象
- MIBC的min ADC、mean ADC、median ADC、第10、25、75、90百分位数ADC均显著低于NMIBC(p=0.002, p<0.001, p<0.001, p=0.003, p=0.004, p<0.001, p<0.001)。
- MIBC的偏度和峰度显著高于NMIBC(p<0.001, p<0.001)。
诊断标准与关键数值
- VI-RADS鉴别MIBC的AUC为0.88,敏感度88.89%,特异度83.61%。
- VI-RADS联合偏度的AUC为0.923(95% CI 0.847-0.969),高于单独VI-RADS的AUC 0.880(95% CI 0.793-0.940)。
临床应用与阅片要点
- 在日常阅片中,可基于DWI评估VI-RADS,并考虑结合体积ADC直方图参数(如偏度)提高鉴别MIBC的准确性。
局限性
- 回顾性研究,样本量较小(80例),可能限制结论的普遍性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The objective of this study was to explore whether volumetric apparent diffusion coefficient (ADC) histogram analysis can provide additional value to Vesical Imaging Reporting and Data System (VI-RADS) in differentiating muscle-invasive bladder cancer (MIBC) from non-muscle-invasive bladder cancer (NMIBC).
MATERIALS AND METHODS: 80 patients were retrospectively reviewed with pathologically proven NMIBC (n = 53) or MIBC (n = 27). All patients underwent MRI including diffusion-weighted imaging (DWI) (b = 0, 800 s/mm2), and the VI-RADS score was evaluated based on DWI. Volumetric ADC histogram parameters were calculated from the volumetric of interest (VOI) on DWI, including the min ADC, mean ADC, median ADC, max ADC, 10th, 25th, 75th, 90th percentiles ADC, skewness, kurtosis, and entropy. The Mann-Whitney U-test was used to compare histogram parameters between NMIBC and MIBC. Receiver operating characteristic analysis was used to evaluate the diagnostic value of each significant parameter.
RESULTS: Among all parameters, the VI-RADS yield the highest Area Under the Curve (AUC, 0.88; sensitivity, 88.89%; specificity, 83.61%). MIBC had significantly lower min ADC, mean ADC, median ADC, 10th, 25th, 75th, and 90th percentiles ADC than NMIBC (p = 0.002, p < 0.001, p < 0.001, p = 0.003, p = 0.004, p < 0.001, p < 0.001). Skewness and kurtosis of MIBC were significantly higher than those of NMIBC (p < 0.001, p < 0.001). The combination of VI-RADS and skewness showed significantly higher AUC (AUC 0.923; 95% CI 0.847-0.969) than only with VI-RADS (AUC 0.880; 95% CI 0.793-0.940).
CONCLUSION: Volumetric ADC histogram analysis and VI-RADS are both useful methods in differentiating MIBC from NMIBC, and the volumetric ADC histogram analysis can provide additional value to VI-RADS.
引用
- Li S, Liang P, Wang Y, et al. Combining volumetric apparent diffusion coefficient histogram analysis with vesical imaging reporting and data system to predict the muscle invasion of bladder cancer. Abdom Radiol (NY). 2021. PMID: 33909091. doi:10.1007/s00261-021-03091-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。