肾脏组织替代物用于多能量CT的可行性及低kV与虚拟单能成像中肾脏病灶强化衰减阈值的估算

Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging.
PubMed 文献 · Invest Radiol · 2021-01-01

本研究通过体模实验评估肾脏组织替代物(KTS)模拟肾实质能量依赖性CT衰减特性的能力,并估算低kV单能和低keV双能虚拟单能成像中明确病灶强化的衰减阈值。结果显示固体KTS(含水量80%)比水-碘溶液更准确模拟平扫肾实质(30 HU),且强化阈值随管电压和keV水平变化,单能CT为16.1-34.3 HU,双能虚拟单能成像为3.2-92.2 HU。

要点

  • 固体KTS(80%水)可准确模拟平扫肾实质约30 HU的衰减,优于水-碘溶液。
  • 明确病灶强化的CT衰减阈值依赖管电压和keV水平,低keV时阈值范围宽。
  • 双能虚拟单能成像在低keV下阈值可达92.2 HU,需注意能量条件对强化判断的影响。

局限性

  • 体模研究,非临床患者验证。
  • 样本量有限,仅100例患者用于平扫肾实质衰减测量。
  • 仅评估两种双能CT扫描仪,结果可能不适用于其他设备。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aims of this study were to assess if kidney tissue surrogates (KTSs) are superior to distilled water-iodine solutions in the emulation of energy-dependent computed tomography (CT) attenuation characteristics of renal parenchyma and to estimate attenuation thresholds for definite lesion enhancement for low-kV single-energy and low-keV dual-energy virtual monoenergetic imaging.

METHODS: A water-filled phantom (diameter, 30 cm) with multiple vials was imaged on a dual-source dual-energy CT (DS-DE) and a single-source split-filter dual-energy CT (SF-DE), both in single-energy mode at 80, 100, 120, 140 kVp and in dual-energy mode at 80/Sn150, 90/Sn150, and 100/Sn150 kVp for DS-DE and AuSn120 kVp for SF-DE. Single-energy images, linear-blended dual-energy images, and virtual monoenergetic imaging at energy levels from 40 to 190 keV were reconstructed. First, attenuation characteristics of KTS in solid and liquid consistencies were compared. Second, solid KTSs were developed to match the CT attenuation of unenhanced renal parenchyma at 120 kVp as retrospectively measured in 100 patients. Third, CT attenuation of KTS-iodine and water-iodine solutions at 8 different iodine concentrations (0-10 mg I/mL) were compared as a function of tube voltage and of keV level using multiple linear regression models. Energy-dependent attenuation thresholds for definite lesion enhancement were calculated.

RESULTS: Unenhanced renal parenchyma at 120 kVp measured on average 30 HU on both scanners in the patient cohort. Solid KTS with a water content of 80% emulated the attenuation of unenhanced renal parenchyma (30 HU) more accurately compared with water-iodine solutions (0 HU). Attenuation difference between KTS-iodine and water-iodine solutions converged with increasing iodine concentration and decreasing x-ray energy due to beam-hardening effects. A slight attenuation difference of approximately 2 HU was found between the 2 CT scanners. Attenuation thresholds for definite lesion enhancement were dependent on tube voltage and keV level and ranged from 16.6 to 33.2 HU and 3.2 to 68.3 HU for single-energy and dual-energy CT scan modes for DS-DE and from 16.1 to 34.3 HU and 3.3 to 92.2 HU for SF-DE.

CONCLUSIONS: Kidney tissue surrogates more accurately emulate the energy-dependent CT attenuation characteristics of renal parenchyma for multienergy CT compared with conventional water-iodine approaches. Energy-dependent thresholds for definite lesion enhancement could facilitate lesion characterization when imaging at different energies than the traditional 120 kVp.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Euler A, Zadory M, Breiding PS, et al. Realistic Kidney Tissue Surrogates for Multienergy Computed Tomography-Feasibility and Estimation of Energy-Dependent Attenuation Thresholds for Renal Lesion Enhancement in Low-kV and Virtual Monoenergetic Imaging. Invest Radiol. 2021. PMID: 33899757. doi:10.1097/RLI.0000000000000790