PI-RADS v2.1与v2在移行带和外周带的比较:读者间一致性与临床显著前列腺癌诊断效能评估
本回顾性研究纳入77例根治性前列腺切除术前接受3.0T多参数MRI的患者,由4名不同经验放射科医生独立使用PI-RADS v2.1和v2对8个区域评分。结果显示v2.1在移行带、外周带及联合区域的读者间一致性和诊断临床显著前列腺癌的AUC均优于v2。
要点
- PI-RADS v2.1较v2可提高不同经验读者间评分一致性。
- v2.1在移行带和外周带诊断临床显著前列腺癌的AUC均更高。
- v2.1有助于缩小经验不同放射科医生间的诊断差异。
核心结论
- PI-RADS v2.1较v2可改善读者间一致性,并可能提高诊断效能。
研究设计与样本
- 回顾性研究,纳入77例根治性前列腺切除术前接受3.0T多参数MRI的连续患者。
- 4名放射科医生(2名经验丰富泌尿放射科医生和2名经验不足放射科医生)独立评分8个区域(6个外周带和2个移行带)。
- 以根治性前列腺切除病理为参考标准,评估读者间一致性和诊断临床显著前列腺癌的AUC。
诊断标准与关键数值
- 以cut-off≥3,所有读者间一致性v2.1优于v2:移行带κ=0.509 vs 0.414,外周带κ=0.686 vs 0.568,联合区域κ=0.644 vs 0.531。
- 以cut-off≥4,所有读者间一致性v2.1优于v2:外周带κ=0.761 vs 0.701,联合区域κ=0.756 vs 0.709。
- 所有读者AUC:v2.1在移行带为0.826-0.907(v2为0.788-0.856),在外周带为0.857-0.919(v2为0.853-0.902)。
临床应用与阅片要点
- 日常阅片采用PI-RADS v2.1评分可能提高不同经验医生间的一致性。
- 在移行带和外周带均可参考v2.1以提升临床显著前列腺癌的诊断效能。
局限性
- 回顾性研究,样本量有限(77例),仅纳入根治性前列腺切除术前患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the interreader agreement and diagnostic performance of the Prostate Imaging Reporting and Data System (PI-RADS) v. 2.1, in comparison with v. 2.
METHODS: Institutional review board approval was obtained for this retrospective study. 77 consecutive patients who underwent a prostate multiparametric magnetic resonance imaging at 3.0 T before radical prostatectomy were included. Four radiologists (two experienced uroradiologists and two inexperienced radiologists) independently scored eight regions [six peripheral zones (PZ) and two transition zones (TZ)] using v. 2.1 and v. 2. Interreader agreement was assessed using κ statistics. To evaluate diagnostic performance for clinically significant prostate cancer (csPC), area under the curve (AUC) was estimated.
RESULTS: 228 regions were pathologically diagnosed as positive for csPC. With a cut-off ≥3, the agreement among all readers was better with v. 2.1 than v. 2 in TZ, PZ, or both zones combined (κ-value: TZ, 0.509 vs 0.414; PZ, 0.686 vs 0.568; both zones combined, 0.644 vs 0.531). With a cut-off ≥4, the agreement among all readers was also better with v. 2.1 than v. 2 in the PZ or both zones combined (κ-value: PZ, 0.761 vs 0.701; both zones combined, 0.756 vs 0.709). For all readers, AUC with v. 2.1 was higher than with v. 2 (TZ, 0.826-0.907 vs 0.788-0.856; PZ, 0.857-0.919 vs 0.853-0.902).
CONCLUSION: Our study suggests that the PI-RADS v. 2.1 could improve the interreader agreement and might contribute to improved diagnostic performance compared with v. 2.
ADVANCES IN KNOWLEDGE: PI-RADS v. 2.1 has a potential to improve interreader variability and diagnostic performance among radiologists with different levels of expertise.
引用
- Urase Y, Ueno Y, Tamada T, et al. Comparison of prostate imaging reporting and data system v2.1 and 2 in transition and peripheral zones: evaluation of interreader agreement and diagnostic performance in detecting clinically significant prostate cancer. Br J Radiol. 2021. PMID: 33882243. doi:10.1259/bjr.20201434
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。