深度学习计算机辅助诊断系统提高前列腺双参数MRI阅片准确性与效率
本研究基于PROSTATEx公开数据集100例前列腺MRI,7名放射科医师在无和有DL-CAD辅助下两次阅片,间隔至少2周,以3名资深放射科医师共识为参考标准。DL-CAD辅助使检测PI-RADS≥4临床显著病例的AUC从0.84提升至0.88(提升4.4%,P=0.010),读片者间一致性Fleiss κ从0.22升至0.36(P=0.003),中位阅片时间从103秒降至81秒(减少21%,P<0.001)。
要点
- DL-CAD辅助可提高检测PI-RADS≥4前列腺癌的AUC(0.84→0.88,P=0.010)。
- DL-CAD辅助使读片者间一致性Fleiss κ从0.22升至0.36(P=0.003)。
- DL-CAD辅助使中位阅片时间从103秒降至81秒,减少21%(P<0.001)。
核心结论
- 使用DL-CAD系统可提高检测高度可疑前列腺病变的诊断准确性,并降低读片者间变异性和阅片时间。
研究设计与样本
- 多阅片者多病例研究,从PROSTATEx Challenge公开数据集连续选取100例前列腺MRI病例,含病理确诊和无前列腺癌病例。
- 7名委员会认证放射科医师在无和有DL-CAD辅助两个阅片组中分别阅片,间隔至少2周,任务为按PI-RADS v2.0定位和分类病变并给出1-5分(0.5递增)怀疑度评分。
- 参考标准为3名经验丰富放射科医师共识阅片。
诊断标准与关键数值
- 检测PI-RADS≥4临床显著病例的平均AUC:无DL-CAD辅助为0.84(95%CI 0.79-0.89),有DL-CAD辅助为0.88(95%CI 0.83-0.94),提升4.4%(95%CI 1.1%-7.7%,P=0.010)。
- 读片者间一致性Fleiss κ从0.22升至0.36(P=0.003)。
- 检测PI-RADS≥3病例的准确性提升2.9%(P=0.10)。
- 中位阅片时间从103秒降至81秒,减少21%(P<0.001)。
临床应用与阅片要点
- DL-CAD辅助可提高检测PI-RADS≥4前列腺癌的AUC并减少读片者间变异,适合用于双参数前列腺MRI阅片。
- DL-CAD辅助可缩短阅片时间,有助于提高工作效率。
局限性
- 研究基于公开数据集PROSTATEx Challenge的100例病例,样本量有限。
- 参考标准为3名放射科医师共识阅片而非全病理对照,可能存在参考标准偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to evaluate the effect of a deep learning based computer-aided diagnosis (DL-CAD) system on radiologists' interpretation accuracy and efficiency in reading biparametric prostate magnetic resonance imaging scans.
MATERIALS AND METHODS: We selected 100 consecutive prostate magnetic resonance imaging cases from a publicly available data set (PROSTATEx Challenge) with and without histopathologically confirmed prostate cancer. Seven board-certified radiologists were tasked to read each case twice in 2 reading blocks (with and without the assistance of a DL-CAD), with a separation between the 2 reading sessions of at least 2 weeks. Reading tasks were to localize and classify lesions according to Prostate Imaging Reporting and Data System (PI-RADS) v2.0 and to assign a radiologist's level of suspicion score (scale from 1-5 in 0.5 increments; 1, benign; 5, malignant). Ground truth was established by consensus readings of 3 experienced radiologists. The detection performance (receiver operating characteristic curves), variability (Fleiss κ), and average reading time without DL-CAD assistance were evaluated.
RESULTS: The average accuracy of radiologists in terms of area under the curve in detecting clinically significant cases (PI-RADS ≥4) was 0.84 (95% confidence interval [CI], 0.79-0.89), whereas the same using DL-CAD was 0.88 (95% CI, 0.83-0.94) with an improvement of 4.4% (95% CI, 1.1%-7.7%; P = 0.010). Interreader concordance (in terms of Fleiss κ) increased from 0.22 to 0.36 (P = 0.003). Accuracy of radiologists in detecting cases with PI-RADS ≥3 was improved by 2.9% (P = 0.10). The median reading time in the unaided/aided scenario was reduced by 21% from 103 to 81 seconds (P < 0.001).
CONCLUSIONS: Using a DL-CAD system increased the diagnostic accuracy in detecting highly suspicious prostate lesions and reduced both the interreader variability and the reading time.
引用
- Winkel DJ, Tong A, Lou B, et al. A Novel Deep Learning Based Computer-Aided Diagnosis System Improves the Accuracy and Efficiency of Radiologists in Reading Biparametric Magnetic Resonance Images of the Prostate: Results of a Multireader, Multicase Study. Invest Radiol. 2021. PMID: 33787537. doi:10.1097/RLI.0000000000000780
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。