文献速递儿科影像泌尿生殖US

儿童肾纤维化剪切波弹性成像的技术可行性与组织学相关性

Technical feasibility and correlations between shear-wave elastography and histology in kidney fibrosis in children.
PubMed 文献 · Pediatr Radiol · 2021-04-24

本研究纳入95例接受肾活检的肾病或肾移植儿童,评估剪切波弹性成像的可行性及观察者内变异,并检验弹性值与纤维化的相关性。凸阵探头测量成功率100%,线性探头仅适用于20%自体肾和50%移植肾;移植患者弹性值和纤维化均更高,但弹性值与纤维化无相关性。

要点

  • 凸阵探头在儿童肾脏弹性测量中可行性最高,线性探头适用范围有限。
  • 弹性值与肾纤维化无相关性,不能替代肾活检评估纤维化。
  • 移植肾患者弹性值和纤维化程度均高于自体肾,但需注意鉴别。

核心结论

  • 儿童肾脏弹性成像使用凸阵探头分析更准确,但弹性值与肾纤维化无相关性。

研究设计与样本

  • 前瞻性研究纳入95例肾病或肾移植儿童及青少年,其中31例为肾移植,所有患儿均行肾活检。
  • 由4名操作者使用凸阵和线性探头测量肾脏弹性,评估可行性和观察者内变异,并与组织学纤维化进行相关性分析。

关键影像表现/征象

  • 凸阵探头测量成功率100%,线性探头仅对20%自体肾和50%移植肾可行。
  • 线性探头测得的弹性值高于凸阵探头(左肾P<0.001,右肾P=0.03)。
  • 同一患儿双肾弹性测量值无差异。
  • 移植患者弹性值和纤维化均更高(凸阵P=0.02,线性P=0.01,整体P=0.04)。

诊断标准与关键数值

  • 观察者内变异度为中等至高度,取决于探头和所测肾脏。
  • 弹性值与纤维化之间无相关性。

临床应用与阅片要点

  • 儿童肾脏弹性成像首选凸阵探头,线性探头因可行性低不作为常规。
  • 报告弹性值时需注意探头类型对测值的影响,避免直接比较。
  • 目前弹性值不能用于评估肾纤维化程度,肾活检仍是参考标准。

局限性

  • 线性探头可行性低导致部分测量缺失,可能影响结果代表性。
  • 观察者内变异度为中等至高度,测量重复性有限。
  • 单中心研究,样本量95例,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Ultrasound elastography has been suggested for assessing organ fibrosis.

OBJECTIVE: To study the feasibility of shear-wave elastography in children with kidney disease and the correlation between elasticity and kidney fibrosis in order to reduce the indications for kidney biopsy and its complications.

MATERIALS AND METHODS: Four operators measured kidney elasticity in children with kidney diseases or transplants, all of whom also had a renal biopsy. We assessed the feasibility and the intraobserver variability of the elasticity measurements for each probe used and each kidney explored. Then we tested the correlation between elasticity measurements and the presence of fibrosis.

RESULTS: Overall, we analyzed 95 children and adolescents, 31 of whom had renal transplant. Measurements with the convex probe were possible in 100% of cases. Linear probe analysis was only possible for 20% of native kidneys and 50% of transplants. Intraobserver variabilities ranged from moderate to high, depending on the probe and kidney studied. Elasticity was higher with the linear probe than with the convex probe (P<0.001 for left kidney and P=0.03 for right kidney). Measurements did not differ from one kidney to another in the same child. Elasticity and fibrosis were both higher in transplant patients (P=0.02 with convex probe; P=0.01 with linear probe; P=0.04 overall). There was no correlation between elasticity and fibrosis.

CONCLUSION: Of the devices used in this work, kidney elastography was more accurately analyzed with a convex probe. Our study did not identify any correlation between elasticity and kidney fibrosis.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Desvignes C, Dabadie A, Aschero A, et al. Technical feasibility and correlations between shear-wave elastography and histology in kidney fibrosis in children. Pediatr Radiol. 2021. PMID: 33893848. doi:10.1007/s00247-021-05068-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。