18-French直肠管置入对多参数前列腺MRI图像质量的影响
本研究比较了技师置入18-French直肠管后全程保留的多参数前列腺MRI(n=97)与未置管者(n=99),采集参数相同,两名放射科医师主观评分并测量直肠直径。置管与ADC图质量改善、DWI畸变减少、直肠气体减少及直肠直径减小相关(p<.001),支持常规置管。
要点
- 18-French直肠管置入可改善前列腺mpMRI的ADC图质量并减少DWI畸变。
- 置管后直肠气体减少、直肠直径减小,有助于减少伪影。
- 研究支持在前列腺mpMRI中常规置入直肠管。
关键影像表现/征象
- 置管后ADC图质量改善(两名读者均p<.001)。
- 置管后DWI畸变减少(两名读者均p<.001)。
- 置管后直肠气体减少(两名读者均p<.001)。
- 置管后直肠直径减小(两名读者均p<.001)。
临床应用与阅片要点
- 日常前列腺mpMRI检查中可考虑由技师置入18-French直肠管并全程保留以改善图像质量。
- 置管有助于减少直肠气体和DWI畸变,阅片时注意其对ADC图质量的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study compared prostate multiparametric MRI (mpMRI) performed using an 18-French rectal tube in place throughout the examination after initial placement by a technologist (n = 97) with mpMRI performed without rectal tube placement (n = 99). Acquisition parameters were otherwise identical. Two radiologists scored subjective image quality and measured rectal diameter. For both readers, rectal tube placement was associated (p < .001) with improved ADC map quality, decreased DWI distortion, decreased rectal gas, and decreased rectal diameter. Findings support routine rectal tube placement for prostate mpMRI.
引用
- Huang YH, Özütemiz C, Rubin N, et al. Impact of 18-French Rectal Tube Placement on Image Quality of Multiparametric Prostate MRI. AJR Am J Roentgenol. 2021. PMID: 33852359. doi:10.2214/AJR.21.25732