肝MRI肝胆期肝-门静脉对比度比值Q-LPC的截断值评估
本研究基于74例接受Gd-EOB-DTPA肝MRI患者的102个肿瘤图像,利用ROC曲线以肿瘤可检出性为标准计算肝胆期Q-LPC的截断值。Q-LPC的AUC为0.858,截断值1.462时敏感度0.747、特异度0.852;Q-LSC的AUC为0.710,截断值1.543时敏感度0.560、特异度0.778,两者AUC差异有统计学意义(p=0.0016)。结论认为Q-LPC可用于肝胆期MRI评估。
要点
- Q-LPC在肝胆期评估肿瘤可检出性的AUC为0.858,优于Q-LSC的0.710(p=0.0016)。
- Q-LPC截断值1.462时敏感度0.747、特异度0.852,可作为肝胆期图像质量参考。
- Q-LSC截断值1.543时敏感度0.560、特异度0.778,诊断效能低于Q-LPC。
核心结论
- Q-LPC可用于肝胆期MRI评估,其基于肿瘤可检出性的截断值为1.462。
- Q-LPC的AUC(0.858)显著高于Q-LSC(0.710),差异有统计学意义(p=0.0016)。
研究设计与样本
- 单中心研究,纳入74例接受Gd-EOB-DTPA肝MRI的肿瘤患者(46男28女,年龄71±8.1岁)。
- 共评估102个肿瘤图像,于注射Gd-EOB-DTPA后10分钟测量Q-LSC和Q-LPC。
- 以肿瘤可检出性(50分制评分≥30分为好)为参考标准,用ROC曲线计算截断值并比较AUC。
诊断标准与关键数值
- Q-LPC的AUC-ROC为0.858(95%CI 0.783-0.933),截断值1.462,敏感度0.747,特异度0.852。
- Q-LSC的AUC-ROC为0.710(95%CI 0.597-0.822),截断值1.543,敏感度0.560,特异度0.778。
- 肿瘤可检出性评分采用50分制,≥30分认为图像质量好。
临床应用与阅片要点
- 在肝胆期阅片前可计算Q-LPC,若低于1.462提示图像对肿瘤检出能力可能不足。
- Q-LPC测量简单,可作为肝胆期图像质量的量化参考指标。
局限性
- 单中心研究,样本量有限(74例患者、102个肿瘤图像)。
- 原文未报告读者间一致性及Q-LPC测量可重复性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To calculate the quantitative liver-portal vein contrast ratio (Q-LPC) cut-off value based on tumour detectability by using receiver operating characteristic (ROC) curves.
MATERIALS AND METHODS: Seventy-four patients with tumours (46 men and 28 women; age, 71 ± 8.1 years), who underwent liver magnetic resonance imaging (MRI) using gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) were enrolled. Some patients were found to have multiple tumours. In total, 102 tumour images were evaluated for quantitative liver-spleen contrast ratio (Q-LSC) and Q-LPC 10 minutes after the administration of Gd-EOB-DTPA. Q-LPC and Q-LSC were compared to assess the cut-off values and usefulness. The ROC curve was evaluated using the method for continuously distributed test results, with a free scale of 50 mm. A score of ≥30 out of 50 points was considered good. Cut-off values of Q-LPC and Q-LSC were then calculated. The areas under the ROC curve (AUCs) were also examined and compared.
RESULTS: The AUC-ROC for Q-LPC was 0.858 (95% confidence interval [CI], 0.783-0.933). The cut-off value was determined to be at 1.462. Sensitivity was 0.747, and specificity was 0.852 at the cut-off value. The AUC-ROC for Q-LSC was 0.710 (95% CI, 0.597-0.822). The cut-off value was at 1.543, the sensitivity was 0.560, and the specificity was 0.778 at the cut-off value. A significant difference was noted between the AUCs (p=0.0016).
CONCLUSION: Q-LPC can be used for hepatobiliary phase MRI evaluation.
引用
- Takatsu Y, Nakamura M, Shiozaki T, et al. Assessment of the cut-off value of quantitative liver-portal vein contrast ratio in the hepatobiliary phase of liver MRI. Clin Radiol. 2021. PMID: 33902888. doi:10.1016/j.crad.2021.03.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。